Juniper Networks QFX5200-32C-AFO

Manual do usuario do conmutador Juniper Networks QFX5200-32C-AFO

Model: QFX5200-32C-AFO

1. Introdución

This manual provides essential instructions for the Juniper Networks QFX5200-32C-AFO Switch. It covers critical aspects of installation, operation, maintenance, and troubleshooting to ensure proper and safe use of the device. Please read this manual thoroughly before operating the switch.

2. Información de seguridade

Observe the following safety guidelines to prevent injury and damage to the equipment:

  • Seguridade eléctrica: Ensure the switch is connected to a properly grounded power source. Do not operate the switch with damaged power cords.
  • Ventilación: Maintain adequate airflow around the switch. Do not block ventilation openings. This model features front-to-back airflow.
  • Manexo: The switch is heavy. Use proper lifting techniques or assistance when moving or installing the unit.
  • Persoal cualificado: A instalación e o mantemento só deben ser realizados por persoal cualificado.
  • Seguridade con láser: This product may contain laser components. Avoid direct exposure to laser beams.

3. Contido do paquete

Verify that your package contains the following items. If any items are missing or damaged, contact your vendor immediately.

  • Juniper Networks QFX5200-32C-AFO Switch
  • Cable(s) de alimentación
  • Kit de montaxe en rack
  • Cable da consola
  • Documentación (Guía de inicio rápido, Información de seguridade)

4. Sobrecarga físicaview

The Juniper Networks QFX5200-32C-AFO is a high-performance, fixed-configuration switch designed for data center and enterprise environments. It features 32 QSFP+/QSFP28 ports and front-to-back airflow for efficient cooling.

Fronte view of Juniper Networks QFX5200-32C-AFO Switch with 32 QSFP+/QSFP28 ports and management ports.

Figure 1: Front panel of the QFX5200-32C-AFO Switch, showing 32 QSFP+/QSFP28 ports, console port, and management Ethernet port.

Fronte angulada view of Juniper Networks QFX5200-32C-AFO Switch.

Figura 2: En ángulo view of the QFX5200-32C-AFO Switch, highlighting its compact 1U form factor and port layout.

Outra fronte angulada view of Juniper Networks QFX5200-32C-AFO Switch.

Figure 3: Alternative angled view of the QFX5200-32C-AFO Switch, providing a clear perspective of the chassis design.

4.1 Compoñentes do panel frontal

  • QSFP+/QSFP28 Ports (32x): High-speed ports for network connectivity.
  • Porto da consola: RJ-45 serial port for local management access.
  • Management Ethernet Port: RJ-45 port for out-of-band management.
  • LEDs de estado: Indicators for system status, port activity, and power.

4.2 Compoñentes do panel traseiro

  • Módulos de alimentación: Redundant, hot-swappable power supplies.
  • Módulos de ventiladores: Hot-swappable fan trays for cooling.

5. Configuración

5.1 Montaxe en rack

  1. Fixe os soportes de montaxe en bastidor fornecidos aos laterais do conmutador usando os parafusos subministrados.
  2. Carefully slide the switch into the rack, aligning the brackets with the rack posts.
  3. Secure the switch to the rack using appropriate rack screws.

5.2 Conexión de alimentación

  1. Ensure the power switches on the power supply modules are in the OFF position.
  2. Connect the power cords to the power supply modules on the rear of the switch.
  3. Plug the other end of the power cords into a grounded AC power outlet.
  4. Flip the power switches on the power supply modules to the ON position.

5.3 Conexións de rede

  1. Insert QSFP+/QSFP28 transceivers into the desired ports on the front panel.
  2. Connect appropriate fiber optic or copper cables to the transceivers.
  3. For management, connect an Ethernet cable to the management port and/or a serial cable to the console port.

6. Funcionamento do interruptor

6.1 Acendido

Once power is connected and switched ON, the system will initiate its boot sequence. Observe the system status LEDs on the front panel. A stable green LED typically indicates normal operation.

6.2 Acceso á configuración inicial

To access the switch for initial configuration:

  • Porto da consola: Connect a computer via a serial cable to the console port. Use a terminal emulator (e.g., PuTTY, Tera Term) with settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.
  • Management Ethernet Port: If the switch has a default IP address, you can connect a computer to the management port and access the web interface or SSH. Refer to Juniper Networks documentation for default IP addresses and login credentials.

7. Mantemento

7.1 Limpeza

Regularly inspect the switch for dust accumulation, especially around ventilation openings. Use a soft, dry cloth to clean the exterior. For internal cleaning, consult a qualified technician or Juniper Networks support.

7.2 Actualizacións de firmware

Comprobe periodicamente o soporte de Juniper Networks website for the latest firmware updates. Keeping the firmware up-to-date ensures optimal performance, security, and access to new features. Follow the provided instructions carefully when performing updates.

7.3 Fan and Power Supply Replacement

The fan modules and power supply modules are hot-swappable. Refer to the detailed Juniper Networks hardware guide for specific replacement procedures to avoid service interruption.

8 Solución de problemas

8.1 Problemas comúns

  • Sen enerxía: Verify power cords are securely connected to both the switch and the power outlet. Check power supply LEDs. Ensure power switches are ON.
  • Sen ligazón no porto: Check the cable connection, ensure the transceiver is properly seated, and verify the link status on the connected device. Check port configuration.
  • O sistema non responde: Attempt to access the switch via the console port. If unresponsive, perform a power cycle (power OFF, wait 30 seconds, then power ON).
  • Problemas de rendemento: Check network load, port error counters, and switch configuration. Ensure proper ventilation to prevent overheating.

For advanced diagnostics and solutions, consult the comprehensive troubleshooting guides available on the official Juniper Networks support websitio.

9. Especificacións

CaracterísticaDetalle
Número de modeloQFX5200-32C-AFO
MarcaRedes de enebro
Portos32x QSFP+/QSFP28
Fluxo de aireFront To Back
Dimensións do produto (L x W x H)17.36 x 22.44 x 3.46 polgadas
Peso do elemento32.5 libras
Material do casoMetal
Dispositivos compatiblesServer, Workstation
UPC657768621314
CorGris

10. Información da garantía

This Juniper Networks QFX5200-32C-AFO Switch is sold as a "Renewed" product by Amazon Renewed. The warranty terms for renewed products typically differ from new products.

Please refer to the specific warranty details provided by Amazon Renewed or the seller, Network Hardware Depot, at the time of your purchase. Standard manufacturer warranties from Juniper Networks may not apply to renewed equipment. Always consult your purchase documentation for precise warranty coverage.

11. Apoio

For technical assistance, comprehensive documentation, software downloads, and further product information, please visit the official Juniper Networks support websitio:

www.juniper.net/us/en/support.html

For inquiries related to your renewed product purchase, including order status, returns, or seller-specific support, please contact the seller directly: Network Hardware Depot.

Documentos relacionados - QFX5200-32C-AFO

Preview Guía de inicio rápido de Juniper Networks QFX5120-32C
Unha guía de inicio rápido para o conmutador Ethernet Juniper Networks QFX5120-32C, que abrangue a instalación, a configuración inicial e a configuración básica para a implementación da rede.
Preview Guía de transceptores e cables ópticos Juniper 400G
Explora os transceptores e cables ópticos de 400 G de Juniper Networks con esta guía completa. Obtén información sobre os factores de forma QSFP-DD, a óptica ZR/ZR+, a modulación PAM4, o DSP, o FEC, a instalación e o mantemento de solucións de redes metropolitanas e centros de datos de alta velocidade.
Preview Guía de instalación e actualización de Juniper Networks Contrail Service Orchestration, versión 5.1
Esta guía ofrece instrucións detalladas para instalar e actualizar Juniper Networks Contrail Service Orchestration (CSO) versión 5.1. Abarca os requisitos de hardware e software, as opcións de implementación, os procedementos de instalación, as tarefas posteriores á instalación e os procesos de actualización para a infraestrutura de rede.
Preview Guía do hardware do cortafuegos SRX4120: instalación e mantemento
Guía completa de hardware para o firewall Juniper Networks SRX4120, que abrangue a instalación, configuración, mantemento e resolución de problemas.
Preview Juniper Validated Design for Metro Ethernet Business Services (JVD)
A comprehensive guide detailing the Juniper Validated Design (JVD) for building and deploying sophisticated Metro Ethernet Business Services (EBS) network architectures using Juniper platforms. Covers EVPN, SR-MPLS, MEF standards, and Cloud Metro concepts for service providers.
Preview Juniper Routing Assurance Quick Start: Onboard Routers
Learn how to onboard routers and monitor their health and performance using Juniper Routing Assurance with this quick start guide. Covers prerequisites, setup, site assignment, and insights for Juniper routers.