This user manual provides essential information for the safe and efficient operation of your AIMS Power Lithium Battery Dual Battery Cabinet Set. This system is designed to integrate with AIMS Power hybrid inverters, providing robust power storage for critical loads, load sharing, and optimizing energy consumption.

The dual battery cabinet set combines two lithium batteries to create a 230VDC 192 AH battery bank, storing 44,228 Watts of usable power. Lithium battery technology offers significant advantages in terms of deeper discharge cycles, lighter weight, and more compact size compared to traditional lead-acid batteries.

Produto rematadoview

AIMS Power Lithium Battery Dual Cabinet Set with one door open revealing batteries

Figure 1: The AIMS Power Lithium Battery Dual Cabinet Set. One cabinet door is open, showing the internal lithium battery modules and wiring connections. The system is designed for robust energy storage.

Dimensions of the AIMS Power Lithium Battery Cabinet

Figura 2: Dimensional view of the AIMS Power Lithium Battery Cabinet. The image indicates a height of 68.75 inches including eye hooks, a depth of 33.75 inches, and a width of 24.75 inches.

Close-up of internal wiring and battery connections within the AIMS Power cabinet

Figura 3: detallada view of the internal wiring and battery connections. This shows the B+, B-, and COM ports, along with an ON/OFF switch and address settings, indicating the modular nature of the battery system.

Configuración e instalación

The AIMS Power Lithium Battery Dual Battery Cabinet Set is delivered by freight with a lift gate. Ensure your shipping location can accept freight deliveries and that someone is available to accept and sign for the shipment.

1. Preparación do sitio

2. Positioning the Cabinets

3. Conexións Eléctricas

This battery cabinet set is designed to work seamlessly with AIMS Power hybrid inverters. Refer to your specific AIMS Power hybrid inverter manual for detailed wiring diagrams and connection procedures.

4. Acendamento inicial

Instrucións de funcionamento

Once properly installed and connected to an AIMS Power hybrid inverter, the battery cabinet set operates as an integral part of your energy system. The inverter manages the charging and discharging of the batteries based on your programmed settings.

AIMS Hybrid Inverter display showing energy flow

Figura 4: Example of an AIMS Hybrid Inverter display. This interface provides real-time information on solar input, battery state of charge, energy flow, emergency power supply, load, and grid status, allowing for comprehensive system monitoring and control.

Energy Management Modes

The AIMS Power hybrid inverter allows for various programmable modes to optimize energy usage:

Refer to your AIMS Power hybrid inverter's user manual for detailed instructions on configuring these operating modes and monitoring system performance.

Mantemento

The AIMS Power Lithium Battery Dual Battery Cabinet Set requires minimal maintenance due to the inherent characteristics of lithium iron phosphate (LiFePO4) batteries. However, regular checks are recommended to ensure optimal performance and longevity.

Comprobacións de rutina

Coidado da batería

Lithium batteries do not require watering or equalization charges like lead-acid batteries. Their advanced Battery Management System (BMS) handles cell balancing and protection.

Resolución de problemas

This section provides guidance for common issues you might encounter. For more complex problems, contact AIMS Power technical support.

ProblemaCausa posibleSolución
O sistema non se acende.Loose battery connections, battery breaker off, inverter fault.Check all battery cable connections. Ensure the battery cabinet's internal breaker is ON. Consult the inverter manual for fault codes.
As baterías non se cargan.Inverter settings, solar input issue, communication error.Verify inverter charging settings. Check solar panel connections and output. Ensure communication cables are properly connected between batteries and inverter.
Reduced battery capacity/runtime.High discharge rates, extreme temperatures, aging batteries.Ensure loads are within system capacity. Verify operating temperature. While lithium batteries have long lifespans, capacity can gradually decrease over many years of use.
Communication error on inverter display.Loose or faulty communication cable, incorrect address settings.Check communication cable connections. Refer to the inverter and battery cabinet manuals for correct address settings.

If you are unable to resolve an issue using the information above, please contact AIMS Power technical support. They are located in Nevada and have a proven history of support.

Especificacións

AtributoValor
Número de modeloKITHY230VBATMS
MarcaOBXECTIVOS Poder
Tipo de bateríaLithium Metal (LiFePO4)
Vol. Nominaltage230 VDC
Capacidade da batería192 Amp Horas (AH)
Total Energy Storage44,228 Watt Hours (WH)
Peso do elemento650 libras
Usos recomendadosOficina, Casa
Fonte de enerxíaAlimentado por batería
País de OrixeChina
Data de primeira dispoñibilidade26 de setembro de 2023

Garantía e Soporte

Información da garantía

For detailed warranty terms and conditions, please refer to the official warranty documentation provided by AIMS Power at the time of purchase or visit the AIMS Power official website. The warranty typically covers manufacturing defects and performance within specified parameters.

Soporte técnico

AIMS Power provides technical support for their products. For assistance with installation, operation, troubleshooting, or any other technical inquiries, please contact AIMS Power directly. Their technical support team is based in Nevada and is available to assist customers.

For contact information, please visit the official AIMS Power websitio web ou consulte a embalaxe do produto.

Documentos relacionados - KITHY230VBATMS

Preview AIMS Power Global LF Series Pure Sine Wave Inverter/Charger User Manual
User manual for the AIMS Power Global LF Series Pure Sine Wave Inverter/Charger. Covers installation, operation, safety, key features like pure sine wave output, battery charging, automatic transfer, and applications in renewable energy, RVs, and vehicles.
Preview Manual do usuario do controlador de carga solar AIMS Power SCC10AFM
Manual de usuario para o AIMS Power SCC10AFM 10 Amp Controlador de carga solar de montaxe encastrada. Abarca as características, a instalación, o funcionamento, a resolución de problemas e as especificacións dos sistemas de baterías de 12 V/24 V.
Preview Manual de instrucións da batería AIMS Power LiFePO4
Manual de instrucións completo para as baterías LiFePO4 de 12 V de AIMS Power (LFP12V50A, LFP12V100A, LFP12V200A), que abrangue as características, a seguridade, a instalación, as especificacións e a garantía.
Preview Manual de usuario del monitor de batería AIMS POWER BATMON500
Manual do usuario do monitor de baterías AIMS POWER BATMON500, que detalla a introdución do produto, as especificacións, a instalación, as conexións eléctricas, a configuración e a integración de aplicacións para varios tipos e aplicacións de baterías.
Preview Manual de instrucións da batería de carriño de golf de litio AIMS Power de 48 V
Comprehensive instruction manual for AIMS Power 48 Volt Lithium Golf Cart Batteries, models LFPGLF105A, LFPGLF150A, and LFPGLF200A. Includes features, installation guide, handling, maintenance, operation, and detailed specifications for golf cart applications.
Preview Manual do usuario da caixa de enerxía solar todo en un AIMS Power
Manual do usuario para a caixa de enerxía solar todo en un AIMS Power (modelo AIO-12V), que detalla a descrición do produto, información de seguridade, instalación, inversor, sistema solar fotovoltaico, batería, posta en marcha, especificacións e garantía.