This manual provides instructions for the safe and efficient operation of the PCE-HVAC 10 Digital Pressure Gauge, designed for HVAC/Refrigeration service.

1. Introdución

The PCE-HVAC 10 Digital Pressure Gauge is a robust measuring instrument engineered for daily use in refrigeration systems and heat pumps. It accurately determines pressure and temperature, supporting commissioning, servicing, and maintenance tasks. The device features a durable metal casing, a 2-way valve block, and comes with two NTC clamp-on temperature sensors and refrigerant hoses for comprehensive measurement capabilities. With 83 preloaded refrigerants and functions like automatic heat pump mode and temperature-compensated density testing, it simplifies complex operations.

2. Información de seguridade

Please read this manual thoroughly before operating the PCE-HVAC 10 Digital Pressure Gauge. Failure to follow safety instructions may result in injury or damage to the device. Keep this manual for future reference.

3. Contido do paquete

Verifique que todos os elementos que se indican a continuación estean presentes no seu paquete:

PCE-HVAC 10 Digital Pressure Gauge kit in carrying case

Image of the PCE-HVAC 10 Digital Pressure Gauge kit, including the main unit, refrigerant hoses, and NTC clamp sensors, neatly arranged in a protective carrying case.

4. Produto rematadoview

The PCE-HVAC 10 is designed for precision and ease of use in demanding HVAC/R environments. Its robust metal casing ensures durability, while the intuitive interface provides clear readings.

Características principais:

Fronte view of PCE-HVAC 10 Digital Pressure Gauge

Fronte view of the PCE-HVAC 10 Digital Pressure Gauge, showcasing its robust casing and clear LCD display.

PCE-HVAC 10 display with hanging fixture

Close-up of the PCE-HVAC 10 display, showing measurement readings and the integrated hanging hook for convenient placement.

5. Configuración

5.1 Instalación da batería

  1. Localiza o compartimento da batería na parte traseira do dispositivo.
  2. Abra a tapa do compartimento.
  3. Insira 4 pilas AA de 1.5 V, asegurando a polaridade correcta.
  4. Pecha a tapa do compartimento da batería de forma segura.

5.2 Connecting Sensors and Hoses

The PCE-HVAC 10 utilizes a 2-way valve block with three connectors for refrigerant hoses and dedicated ports for NTC clamp sensores.

PCE-HVAC 10 connection ports

Detallado view of the PCE-HVAC 10's connection ports for NTC clamp sensors and refrigerant hoses.

PCE-HVAC 10 2-way valve block

Lado view of the PCE-HVAC 10 showing the metal 2-way valve block with three connectors for refrigerant hoses.

Refrigerant hoses for PCE-HVAC 10

The three color-coded refrigerant hoses (red, blue, yellow) included with the PCE-HVAC 10, used for connecting to HVAC systems.

6. Instrucións de funcionamento

6.1 Encendido/apagado

Manteña premido o botón de acendido (normalmente marcado con /) para acender ou apagar o dispositivo.

6.2 Navegación por menús

Usa o MODO button to cycle through different measurement modes or display screens. The SET button is used to confirm selections or enter settings menus. Use the arrow buttons (/) to navigate options or adjust values. The ESC button allows you to exit a menu or cancel an operation.

6.3 Selección de refrixerantes

The PCE-HVAC 10 has 83 preloaded refrigerants. To select the appropriate refrigerant for your system:

  1. Enter the refrigerant selection menu (refer to the device's on-screen prompts or specific button combination).
  2. Use the arrow buttons to scroll through the list of refrigerants.
  3. Preme SET to confirm your selection. The selected refrigerant will be displayed on the measurement screen.

6.4 Realización de medicións

Once the sensors and hoses are connected and the refrigerant is selected, the device will display real-time pressure and temperature readings. Ensure proper connection to the HVAC/R system for accurate measurements.

6.5 Using the 2-Way Valve Block

The metal 2-way valve block allows for controlled charging, evacuation, and testing of refrigeration systems. Operate the valves carefully to manage refrigerant flow and pressure.

6.6 Funcións especiais

Technician using PCE-HVAC 10 on HVAC system

A technician using the PCE-HVAC 10 Digital Pressure Gauge to monitor an HVAC system, with hoses connected.

PCE-HVAC 10 display showing measurements

Close-up of the PCE-HVAC 10 display showing real-time pressure and temperature readings for a selected refrigerant.

7. Mantemento

7.1 Limpeza

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no moisture enters the device openings.

7.2 Substitución da batería

Replace the batteries when the low battery indicator appears on the display. Follow the battery installation steps outlined in Section 5.1.

7.3 Almacenamento

When not in use, store the PCE-HVAC 10 in its protective carrying case in a dry environment. The recommended storage temperature range is -20 to 60°C / -4 to 140°F with a relative humidity of 10% to 95%.

8 Solución de problemas

If you encounter issues with your PCE-HVAC 10, consider the following common solutions:

For persistent issues, contact PCE Instruments customer support.

9. Especificacións

ParámetroValor
Dimensións do produto8.03 x 4.57 x 2.56 polgadas
Peso do elemento1.7 libras (768 g)
Rango de medición de presión-1 a +60 bar
Precisión da presión0.5% FS
Rango de medición de temperatura-10 a +200 °C / 14 a 392 °F
Resolución de temperatura0.1 °C / 0.18 °F
Fonte de alimentación4 pilas AA de 1.5 V
Clase de protecciónIP42
Temperatura de funcionamentoDe 0 a 45 °C / 32 a 113 °F
Humidade de funcionamento10% a 95% RH (sen condensación)
Temperatura de almacenamento-20 a 60 °C / -4 a 140 °F
Humidade de almacenamento10% a 95% RH (sen condensación)

10. Garantía e soporte

PCE Instruments products are manufactured under strict quality control. This product is covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product or visit the PCE Instruments websitio web para obter información detallada sobre os termos e condicións da garantía.

For technical support, service, or calibration, please contact PCE Instruments directly. Our qualified technicians are available to assist you with any questions or issues you may have regarding the PCE-HVAC 10 Digital Pressure Gauge.

Información de contacto de PCE Instruments:
Por favor visite www.pce-instruments.com para obter datos de contacto específicos da súa rexión.

Documentos relacionados - PCE-HVAC 10

Preview PCE-RRU 10 Refrigerant Recovery Device User Manual
User manual for the PCE-RRU 10 Refrigerant Recovery Device, detailing its specifications, operation, safety guidelines, and troubleshooting.
Preview Manual de usuario do medidor de vibracións PCE-VT 3800/3900
Manual de usuario dos medidores de vibracións PCE-VT 3800 e PCE-VT 3900 de PCE Instruments. Abarca as especificacións detalladas, o funcionamento, os modos de medición, o rexistro de datos, a FFT, as RPM, as medicións de ruta, a seguridade e a calibración para unha monitorización eficaz do estado da máquina.
Preview PCE-RRM 250 Refrigerant Recovery Machine Operating Manual
Comprehensive operating manual for the PCE-RRM 250 Refrigerant Recovery Machine by PCE Instruments. Covers safety, operation, specifications, parts, recovery methods, and troubleshooting for HVAC professionals.
Preview Manual do usuario - Dinamómetro PCE-FM 200 / PCE-FM 50N / PCE-FM 500N
Manual de usuario dos dinamómetros PCE-FM 200, PCE-FM 50N e PCE-FM 500N de PCE Instruments. Este documento proporciona información detallada sobre as precaucións de seguridade, as especificacións, a descrición do dispositivo, o funcionamento, a calibración e a eliminación.
Preview Analizador de humidade PCE-UX 3081/3081WQ: Instrucións de funcionamento e guía técnica
Instrucións de funcionamento completas e especificacións técnicas para os analizadores de humidade PCE-UX 3081 e PCE-UX 3081WQ. Aprenda sobre a configuración, o funcionamento, a seguridade, o mantemento e a resolución de problemas para unha análise precisa de humidade e materia seca mediante métodos termogravimétricos.
Preview Manual do usuario do medidor de espesor ultrasónico PCE-TG 75 / PCE-TG 150
Manual de usuario completo para os medidores de espesor ultrasónicos PCE-TG 75 e PCE-TG 150, que abrangue as especificacións, o funcionamento, a calibración, o mantemento e a resolución de problemas.