ACiQ ACiQ-60-HPD

ACiQ 5 Ton 16 SEER2 Heat Pump Condenser

Model: ACiQ-60-HPD

Marca: ACiQ

Introdución

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 5 Ton 16 SEER2 High Efficiency Heat Pump Condenser. Please read all instructions carefully before installation and use. Professional installation by a certified technician is required to ensure proper function and warranty validity.

ACiQ 5 Ton 16 SEER2 Heat Pump Condenser outdoor unit

Figure 1: ACiQ 5 Ton 16 SEER2 Heat Pump Condenser outdoor unit.

Configuración e instalación

Installation of the ACiQ Heat Pump Condenser requires specialized knowledge and tools. It must be performed by a qualified HVAC technician. Key considerations include:

  • Colocación da unidade exterior: Ensure adequate clearance around the unit for proper airflow and maintenance. The compact design allows for a smaller footprint compared to traditional units.
  • Refrigerante: This unit uses R-454B refrigerant. Proper handling and charging procedures must be followed.
  • Unidade de tratamento de aire: The system supports a multi-positional air handler unit, allowing for upflow, downflow, or horizontal installation to suit various ducting designs.
  • Conexións eléctricas: All electrical wiring must comply with local codes and standards.
Diagram showing ACiQ outdoor unit size comparison to traditional unit

Figure 2: Outdoor unit size comparison, highlighting the ACiQ's smaller footprint.

Diagram showing multi-positional air handler unit installation options

Figure 3: Multi-positional air handler unit for flexible installation (upflow, downflow, horizontal).

Vídeo 1: Rematadoview of ACiQ HPD/EHPD Condenser and System features, including installation flexibility.

Instrucións de funcionamento

Your ACiQ Heat Pump Condenser is designed for high efficiency and reliable performance across a wide range of temperatures. It features advanced inverter technology for precise temperature control and reduced energy consumption.

  • Rango de temperatura: This unit delivers reliable warmth down to -22°F and provides effective cooling up to 122°F.
  • Funcionamento silencioso: The inverter technology ensures whisper-quiet operation, minimizing noise disruptions.
  • Control intelixente: Compatible with Wi-Fi smart thermostats for convenient control and optimization of your home's climate.
Image showing ACiQ unit operating in extreme cold and extreme heat

Figure 4: The ACiQ unit's capability to operate in extreme cold (down to -22°F) and extreme heat (up to 122°F).

Image highlighting the quiet operation of the ACiQ heat pump

Figure 5: The ACiQ heat pump operates quietly, ensuring no interruptions.

Video 2: ACiQ HPD System overview, demonstrating its performance and features.

Mantemento

Regular maintenance is crucial for the longevity and efficiency of your ACiQ Heat Pump Condenser. While some tasks can be performed by the homeowner, annual professional servicing is highly recommended.

  • Función de autolimpeza: The unit features a self-cleaning mechanism that automatically clears debris, reducing the need for frequent manual cleaning.
  • Substitución do filtro: Regularly check and replace air filters in your indoor air handler unit as per manufacturer recommendations to maintain optimal airflow and air quality.
  • Inspección profesional: Schedule annual inspections and tune-ups with a certified HVAC technician to ensure all components are functioning correctly and to prevent potential issues.
Image showing the self-cleaning feature of the ACiQ unit

Figure 6: The ACiQ unit's self-cleaning feature automatically clears debris.

Resolución de problemas

If you experience issues with your ACiQ Heat Pump Condenser, consider the following basic troubleshooting steps. For complex problems, always contact a qualified technician.

  • Sen enerxía: Comprobe o disxuntor e asegúrese de que a unidade estea conectada correctamente á fonte de alimentación.
  • Insufficient Heating/Cooling: Verify thermostat settings, check air filters for blockage, and ensure outdoor unit is free of obstructions.
  • Ruídos pouco comúns: Minor noises are normal during operation. However, loud or persistent unusual noises may indicate a problem and require professional inspection.
  • Códigos de erro: If your thermostat or unit displays an error code, consult your technician or the full product manual for specific meanings and solutions.

Do not attempt to repair internal components yourself. This can void your warranty and pose safety risks.

Especificacións

CaracterísticaDetalle
Nome da marcaACiQ
Número de modeloACiQ-60-HPD
Dimensións do produto16.34" D x 37.48" W x 52.48" H
Eficiencia (SEER2)16 SEER2 (18.0 SEER)
Capacidade5 Ton (60,000 BTU) / 4.69 Tons
Nivel de ruído56 decibeis
Tipo de instalaciónSistema dividido
Factor de formaSistema dividido
Características especiaisInverter Condenser, Learning System
RefrixeranteR-454B
Fonte de enerxíaEléctrico con cable
Cooling capacity chart for ACiQ heat pump

Figure 7: Cooling Capacity performance at various ambient temperatures.

Heating capacity chart for ACiQ heat pump

Figure 8: Heating Capacity performance at various ambient temperatures.

Información da garantía

Your ACiQ Heat Pump Condenser comes with a comprehensive warranty:

  • Garantía de pezas de 7 anos
  • Garantía do compresor de 12 anos

These warranty terms are valid when the unit is installed by a certified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records for warranty claims.

Image detailing ACiQ warranty coverage terms

Figure 9: Warranty coverage terms for ACiQ products.

Apoio

For technical assistance, service, or any questions regarding your ACiQ Heat Pump Condenser, please contact your certified ACiQ dealer or the manufacturer's support team. Our dedicated support team is available to provide assistance.

Visit the official ACiQ websitio para obter recursos adicionais, preguntas frecuentes e información de contacto: ACiQ Store

Documentos relacionados - ACiQ-60-HPD

Preview ACiQ Extreme+ Ducted Air Handler Installation Manual (18K-60K)
Installation manual for ACiQ Extreme+ Ducted Air Handler (18K-60K) models, detailing safety, unit setup, refrigerant, wiring, and testing procedures for qualified technicians.
Preview ACiQ High Efficiency Heat Pump System Quick Start Guide: Standard and Extreme Series with R-454B
Quick start guide for installing and connecting ACiQ High Efficiency Heat Pump Systems (Standard and Extreme Series with R-454B). Covers thermostat wiring, DIP switch settings, and basic setup for various installation scenarios.
Preview ACiQ Ducted Air Handler Installation Manual: Models 12K-60K
Comprehensive installation manual for ACiQ Ducted Air Handler units, covering models from 12K to 60K BTU. Provides detailed instructions, safety precautions, wiring diagrams, and specifications for proper installation and setup.
Preview ACiQ EXTREME+ Ducted Air Handler Installation Manual (18K-60K)
Comprehensive installation manual for ACiQ EXTREME+ Ducted Air Handler systems, covering models from 18K to 60K BTU. Includes safety precautions, installation procedures, wiring, and testing.
Preview ACiQ Wall-Mounted Air Handler & Extreme Heat Single-Zone Condenser Installation & Owner's Manual
This manual provides detailed installation, operation, and safety guidelines for ACiQ wall-mounted air handlers and extreme heat single-zone condensers, covering models ACIQ-06W-HH-MD through ACIQ-24ZPL-HP230C.
Preview Manual de instalación do condensador de zona única ACiQ Extreme Heat e do controlador de aire para condutos ocultos
Manual de instalación para os sistemas de tratamento de aire por condutos ocultos e condensadores de zona única ACiQ Extreme Heat (modelos ACIQ-09CD-HH-MC a ACIQ-60CD-HH-MC e ACIQ-09ZPL-HP230C a ACIQ-60ZPL-HP230C). Inclúe a seguridade, os pasos de instalación e as especificacións.