The Irfora W2023 Electronic Humidity Controller is an intelligent digital device designed for precise humidity management. It features a clear 1.0-inch LCD display and two control buttons for easy operation. Equipped with a high-precision humidity sensor, this controller can accurately measure and regulate ambient humidity. It supports both humidification and dehumidification modes, making it suitable for a wide range of applications such as egg incubators, greenhouse planting, and humidity control in storage areas or computer rooms.

2. Contido do paquete

Comprobe que todos os elementos estean presentes no paquete:

  • 1 x Irfora W2023 Electronic Humidity Controller
  • 1 x Humidity Sensor (integrated)
  • 1 x Power Cord (US Plug variant)
  • 1 manual de instrucións (inglés)
  • Accessories: Suction cup, screws (for mounting options)

Video: This video demonstrates the appearance of the humidity controller and its included accessories, such as the sensor, power cord, and mounting hardware.

3. Especificacións

ParámetroValor
Nome do produtoDigital Humidity Controller
Número de modelo do artigoW2023
Alimentación VoltageCA 110-220 V
Rango de medición de humidade0%RH - 99%RH
Humidity Control Accuracy0.1% RH
Tipo de saídaSaída directa
Potencia de saída1500 W
Capacidade de saídaMáx. 10A
Tamaño da aparencia118 * 60 * 33mm (4.65 * 2.36 * 1.30 inches)
Peso do elemento160 g (5.64 onzas)
Image showing the Irfora W2023 Humidity Controller with its technical specifications listed next to it.

Image: Detailed technical specifications of the Irfora W2023 Humidity Controller, including model number, power, and dimensions.

4. Configuración

Follow these steps to set up your humidity controller:

  1. Montaxe: The controller can be wall-mounted using the provided screws or attached to a smooth surface using the suction cup. Ensure the mounting location is stable and allows for easy access to the display and buttons.
  2. Colocación do sensor: Connect the humidity sensor to the controller. Place the sensor in the environment where humidity needs to be monitored and controlled. Ensure the sensor is not directly exposed to water or extreme conditions that could affect its accuracy.
  3. Conexión de alimentación: Plug the controller's power cord into a suitable 110-220V AC power outlet.
  4. Conexión do dispositivo: Plug your humidification or dehumidification device (e.g., humidifier, dehumidifier) into the output socket of the controller.
Image showing the Irfora W2023 Humidity Controller with a US plug and an EU plug option, highlighting the plug type.

Image: The Irfora W2023 Humidity Controller, illustrating the US plug type.

Image showing the Irfora W2023 Humidity Controller with labels pointing to its output indicator, actual humidity display, and humidity adjustment buttons.

Imaxe: Fronte view of the controller, detailing the display and button functions.

5. Instrucións de funcionamento

The controller automatically determines the operating mode (humidification or dehumidification) based on your set start and stop humidity values.

5.1 Setting Humidification Mode

Humidification mode is activated when the Start Humidity < Stop Humidity.

  1. Set Start Humidity: Long press the 'Up' button. When the display flashes, use the 'Up' and 'Down' buttons to adjust the desired starting humidity value.
  2. Set Stop Humidity: Long press the 'Down' button. When the display flashes, use the 'Up' and 'Down' buttons to adjust the desired stopping humidity value.
  3. The controller will automatically save the settings after flashing for three seconds.

ExampLe: To control a humidifier to stop at 65%RH and restart at 50%RH:

  • First, ensure the controller is in humidification mode (Start Humidity < Stop Humidity).
  • Press and hold the 'Up' button to set the startup humidity to 50%RH. The display will flash, then automatically return after three seconds.
  • Press and hold the 'Down' button to set the stop humidity to 65%RH. The display will flash, then automatically save and exit after three seconds.

5.2 Setting Dehumidification Mode

Dehumidification mode is activated when the Start Humidity > Stop Humidity.

  1. Set Start Humidity: Long press the 'Up' button. When the display flashes, use the 'Up' and 'Down' buttons to adjust the desired starting humidity value.
  2. Set Stop Humidity: Long press the 'Down' button. When the display flashes, use the 'Up' and 'Down' buttons to adjust the desired stopping humidity value.
  3. The controller will automatically save the settings after flashing for three seconds.

ExampLe: To control a dehumidifier to stop at 26%RH and restart at 28%RH:

  • First, ensure the controller is in dehumidification mode (Start Humidity > Stop Humidity).
  • Press and hold the 'Up' button to set the startup humidity to 28%RH. The display will flash, then automatically return after three seconds.
  • Press and hold the 'Down' button to set the stop humidity to 26%RH. The display will flash, then automatically save and exit after three seconds.
Image illustrating the logic for humidification mode (Start Humidity < Stop Humidity) and dehumidification mode (Start Humidity > Stop Humidity) on the controller display.

Image: Visual representation of how the controller automatically identifies humidification or dehumidification mode based on set humidity values.

Image showing detailed steps for setting humidification and dehumidification modes with specific humidity values as examples.

Image: Step-by-step guide for setting humidification and dehumidification parameters.

Video: This video demonstrates the operational settings for a similar temperature and humidity controller, including setting temperature, humidity, and timer functions.

6. Aplicacións

The Irfora W2023 Humidity Controller is versatile and can be used in various settings:

  • Incubation Breeding: Maintain precise humidity levels for successful egg hatching.
  • Greenhouse/Vegetable Planting: Optimize humidity for plant growth and health.
  • Aquaculture Farms: Control humidity for aquatic environments.
  • Warehouses/Computer Rooms: Prevent moisture damage and ensure optimal operating conditions for sensitive equipment.
Image collage showing the humidity controller being used in various applications: an egg incubator, a greenhouse, a computer server room, and a farm for dehumidification.

Imaxe: Examples of the humidity controller in use for incubation, greenhouse, computer room, and farm applications.

7. Mantemento

To ensure optimal performance and longevity of your Irfora W2023 Electronic Humidity Controller:

  • Limpeza: Regularly wipe the controller and sensor with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
  • Coidados do sensor: Keep the humidity sensor clean and free from dust or debris. Do not immerse the sensor in water.
  • Almacenamento: Se vai gardar o dispositivo durante un período prolongado, desconécteo da corrente e gárdeo nun lugar fresco e seco.

8 Solución de problemas

If you encounter issues with your humidity controller, refer to the following common problems and solutions:

  • Sen alimentación/Pantalla apagada: Check if the power cord is securely plugged into a live outlet. Ensure there are no power outages.
  • Lecturas inexactas: Verify the sensor is clean and properly placed. Avoid placing the sensor near heat sources, direct sunlight, or areas with poor air circulation.
  • Device Not Activating: Confirm that your humidification/dehumidification device is correctly plugged into the controller's output socket and is functioning independently. Check your set start and stop humidity values to ensure they are configured correctly for the desired mode (humidification or dehumidification).
  • Output Indicator Not Lighting Up: If the output indicator (OUT) is not lit when the connected device should be active, check the set humidity parameters. The indicator lights up when there is output at the output socket.

Se os problemas persisten, póñase en contacto co servizo de atención ao cliente.

9. Información de seguridade

Please read and follow these safety precautions:

  • Non opere o dispositivo coas mans molladas.
  • Non desmonte nin modifique o controlador.
  • Keep the device away from water and high humidity environments (other than the sensor tip).
  • Asegúrese de que a fonte de alimentación voltage matches the device's requirements (110-220V).
  • Do not exceed the maximum output capacity of 10A / 1500W.