Pulsar PGiPAIRB4

Pulsar PGiPAIRB4 Inverter Generator Parallel Kit

Manual de instrucións

Introdución

This manual provides essential instructions for the safe and efficient use of your Pulsar PGiPAIRB4 Inverter Generator Parallel Kit. This kit allows you to connect two compatible Pulsar inverter generators to double their power output, providing increased electrical capacity for various applications, including RV use.

Compatible Pulsar Generator Models: PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO.

Información de seguridade

Always read and understand all safety warnings and instructions in this manual and the manuals of your connected generators before operation. Failure to follow these instructions can result in serious injury or property damage.

  • Ensure all connections are secure before starting generators.
  • Operate generators in a well-ventilated area to prevent carbon monoxide poisoning.
  • Non opere en condicións húmidas.
  • Keep children and pets away from operating equipment.
  • Always turn off generators and disconnect spark plug wires before performing any maintenance or making connections.

Contido do paquete

Verifica que todos os elementos estean presentes no teu paquete:

  • Pulsar PGiPAIRB4 Parallel Kit Unit
  • Connection Cables (integrated)
  • Manual de usuario (este documento)
Pulsar PGiPAIRB4 Parallel Kit unit with cables

Image: The Pulsar PGiPAIRB4 Parallel Kit unit, showing the main box with receptacles and circuit breakers, and the integrated connection cables extending from it.

Configuración e conexión

Follow these steps to connect your parallel kit to two compatible Pulsar inverter generators:

  1. Preparación: Ensure both generators are turned off, cooled down, and disconnected from any loads. Place the generators on a level, stable surface in a well-ventilated area.
  2. Connect Parallel Cables: Locate the parallel connection ports on each generator. These are typically color-coded (red and black) and may have specific shapes.
    Close-up of parallel connection cables

    Imaxe: Primeiro plano view of the parallel kit's connection cables, showing the red and black connectors designed to plug into the generators.

    Connect the red cable from the parallel kit to the red parallel port on the first generator. Connect the black cable from the parallel kit to the black parallel port on the first generator. Repeat this process for the second generator.
    Close-up of parallel connection adapters

    Image: Various parallel connection adapters and plugs, illustrating the types of connections used for linking generators.

  3. Conexións seguras: Ensure all connections are firmly seated and secure. Loose connections can cause arcing or power interruptions.
  4. Colocación final: Position the parallel kit unit in a safe, accessible location, away from exhaust fumes and moisture.
    Two Pulsar generators connected with the parallel kit

    Image: Two Pulsar inverter generators shown from the rear, with the PGiPAIRB4 Parallel Kit connected to their respective parallel ports, demonstrating a complete setup.

Instrucións de funcionamento

Once the parallel kit is securely connected to both generators:

  1. Start Generators: Start both inverter generators according to their individual operating instructions. Allow them to run for a few moments to stabilize.
  2. Conectar cargas: Plug your electrical loads into the receptacles on the PGiPAIRB4 Parallel Kit.
    • The L14-50 receptacle provides 120/240V output at 50 amps.
    • The L14-30 receptacle provides 120/240V output at 30 amps.
  3. Monitor: Observe the generator and parallel kit for proper operation. The circuit breakers on the parallel kit will trip if an overload occurs.
  4. Apagar: To shut down, first disconnect all loads from the parallel kit. Then, turn off both generators according to their individual instructions. Finally, disconnect the parallel kit cables.

Mantemento

The Pulsar PGiPAIRB4 Parallel Kit requires minimal maintenance. Follow these guidelines:

  • Keep the unit clean and free of dirt, dust, and moisture.
  • Inspect cables and connectors regularly for any signs of wear, damage, or corrosion. Replace if necessary.
  • Store the kit in a dry, protected area when not in use.

Resolución de problemas

ProblemaCausa posibleSolución
No power output from parallel kit.
  • Generators not started.
  • Conexións soltas.
  • O interruptor automático disparou.
  • Incompatible generators.
  • Ensure both generators are running.
  • Check all parallel cable connections.
  • Reset the circuit breaker on the parallel kit.
  • Verify generators are listed as compatible models.
O disyuntor salta con frecuencia.
  • Condición de sobrecarga.
  • Faulty appliance.
  • Reduce the total electrical load.
  • Test appliances individually to identify faulty ones.

Especificacións

  • Modelo: PGiPAIRB4
  • Vol. De saídatage: 120/240 V
  • Frecuencia de saída: 60 Hz
  • L14-50 Receptacle: 50 Amps
  • L14-30 Receptacle: 30 Amps
  • Xeradores compatibles: Pulsar PGDA70BiSCO, PGD95BiSCO, PGD105TiSCO
  • Dimensións do produto: 12 x 9 x 4 polgadas
  • Peso do artigo: 3 libras
  • Fabricante: Pulsar

Información da garantía

For detailed warranty information regarding your Pulsar PGiPAIRB4 Parallel Kit, please refer to the warranty card included with your purchase or visit the official Pulsar Products websitio. Garda o comprobante de compra para reclamacións de garantía.

Atención ao cliente

If you have any questions, require technical assistance, or need to order replacement parts, please contact Pulsar Customer Support:

  • Websitio: www.pulsarproducts.com
  • Refer to your product registration or warranty documentation for specific contact numbers or email addresses.

Documentos relacionados - PGiPAIRB4

Preview Manual do operador do xerador inversor de combustible dual Pulsar de 9500 vatios
Este manual do operador proporciona instrucións completas para o xerador inversor de combustible dual Pulsar PGD95BiSCO de 9500 vatios, que abarcan as precaucións de seguridade, o funcionamento, o mantemento e a resolución de problemas.
Preview Manual do operador do xerador de gasolina inversor Pulsar PG2200BiS
Manual completo do operador para o xerador portátil de gasolina con inversor Pulsar PG2200BiS, que abrangue a seguridade, o funcionamento, o mantemento e a resolución de problemas para garantir un rendemento fiable.
Preview Pulsar PG2000iS/PG2300iS Portable Inverter Generator Operator's Manual
This operator's manual provides essential information for the safe operation, assembly, maintenance, and troubleshooting of the Pulsar PG2000iS and PG2300iS portable inverter gasoline generators. Learn how to use your generator effectively and safely.
Preview Manual do operador do xerador inversor Pulsar de 1600 vatios PGD16iSCO
Manual completo do operador para o xerador inversor Pulsar PGD16iSCO de 1600 vatios. Inclúe instrucións de seguridade detalladas, procedementos de funcionamento, programas de mantemento, guías de resolución de problemas e especificacións técnicas para un uso seguro e eficiente.
Preview Manual do operador do xerador de gasolina inversor Pulsar PG2300iSCO
Manual completo do operador para o xerador de gasolina inversor Pulsar PG2300iSCO. Esta guía abrangue información esencial, incluíndo normas de seguridade, características do produto, instrucións de montaxe, procedementos de funcionamento detallados, programas de mantemento, consellos para a resolución de problemas e un diagrama de cableado para un uso seguro e eficaz do xerador.
Preview Manual do operador do xerador inversor Pulsar PG4500BiSRCO
Manual do operador do xerador inversor Pulsar PG4500BiSRCO, que abrangue a seguridade, as características, o funcionamento, o mantemento e a resolución de problemas para o uso de combustible dual con gasolina e GLP.