Manual do usuario do rexistrador de datos de temperatura e humidade en tempo real Elitech Loget 260-TH 4G

1. Introdución

This manual provides detailed instructions for the setup, operation, and maintenance of the Elitech Loget 260-TH 4G Real-time Temperature Humidity Data Logger. This device is designed for monitoring temperature, humidity, light, shock, and location in various cold chain applications, providing real-time data transmission via 4G network.

1.1. Contido do paquete

  • Elitech Loget 260-TH Data Logger (Reusable version)
  • Built-in 4G SIM Card
  • Manual de usuario
  • Cable USB Tipo-C

2. Produto rematadoview

The Loget 260-TH is a multi-sensor data logger equipped with a display and control buttons for easy interaction. It features internal sensors for temperature, humidity, light, and shock, along with LBS (Location-Based Service) for location tracking.

Elitech Loget 260-TH Data Logger with labeled parts

Figure 2.1: Elitech Loget 260-TH Data Logger with numbered components.

2.1. Identificación de compoñentes

  1. Pantalla LCD: Shows current readings, status, and alerts.
  2. Luz indicadora LED: Provides visual status updates (e.g., OK, Alarm).
  3. Activate/Airplane Mode Button: Used to activate the device or toggle airplane mode.
  4. Sensor interno: Mide a temperatura e a humidade ambiente.
  5. Back Hanging Hole: For mounting or securing the device.
  6. Botón Inicio / Parada: Initiates or terminates data logging.
  7. Número de serie: Unique identifier for the device.
  8. Sensor de luz: Detects ambient light levels.
  9. Data Transmission Indicator: Shows network activity and data upload status.

2.2. Características clave

  • Double Data Security: Features offline storage for up to 100,000 points to prevent data loss and supports shadow data recording for continuous monitoring even if logging is mistakenly stopped.
  • Multi-Source Sensing: Monitors internal temperature (-30~60℃), humidity (0~100%RH), light (0~52000Lux), shock (0g~16g), and location (LBS). Optional external sensors for pH value or CO2 are available separately.
  • Remote Monitoring via APP/Web: Real-time data is uploaded to the Elitech iCold Cloud platform via a built-in 4G SIM card. Upload intervals are configurable from 1 minute to 24 hours.
  • Comprehensive Alarm System: Cloud-based alarms can be received via Elitech iCold APP, SMS, Email, or the web platform. The device also provides local sound, screen, and indicator light alarms for offline events.
  • Auto Flight Mode & Electronic Fence: Complies with Do160 for aviation safety. Flight mode can be activated manually, scheduled, or automatically via an electronic fence (custom area activation).
  • iCold Platform: A cloud-based platform compatible with RCW series products for real-time monitoring, automatic alerts, online data analysis, and management. It complies with FDA CFR 21 Part 11 requirements and supports iOS and Android apps.

3. Configuración

3.1. Carga inicial

Before first use, connect the Loget 260-TH to a power source using the provided USB Type-C cable and a standard USB charger (not included) to ensure the internal battery is fully charged. The battery indicator on the LCD will show charging status.

3.2. Device Activation and Platform Connection

  1. Encendido: Press and hold the 'Start/Stop' button for a few seconds until the device powers on and the LCD screen illuminates.
  2. Conexión de rede: The built-in 4G SIM card will automatically attempt to connect to the network. The signal strength indicator on the LCD will show connection status.
  3. iCold Account Setup:
    • Download the Elitech iCold APP from your mobile app store or visit the Elitech iCold web plataforma (http://new.i-elitech.com).
    • Rexístrate para obter unha nova conta ou inicia sesión se xa tes unha.
    • Add your Loget 260-TH device to your account using the serial number found on the device (refer to Figure 2.1, item 7).
  4. Configuración: Once added, you can configure logging parameters such as upload interval, alarm thresholds, and sensor settings via the iCold platform.

4. Instrucións de funcionamento

4.1. Starting and Stopping Logging

  • Comezar a rexistrar: Press and hold the 'Start/Stop' button until the logging indicator appears on the LCD. The device will begin recording data according to the configured settings.
  • Deixar de rexistrar: Press and hold the 'Start/Stop' button again until the logging indicator disappears. Data logging will cease.

4.2. Modo avión

Airplane mode disables all wireless communication (4G) to comply with aviation regulations. Data logging continues internally.

Elitech Loget 260-TH Data Logger displaying Flight Mode feature

Figure 4.1: Loget 260-TH illustrating Flight Mode activation methods.

  • Activación manual: Press the 'Activate/Airplane Mode' button (Figure 2.1, item 3) to toggle airplane mode on or off.
  • Scheduled Activation: Configure specific times for airplane mode activation via the iCold platform.
  • Electronic Fence Activation: Set up a custom geographical area in the iCold platform. The device will automatically enter airplane mode upon entering this area and exit upon leaving.

4.3. Data Access and Alarms

Elitech Loget 260-TH Data Logger next to a smartphone displaying the iCold app interface with data graphs

Figure 4.2: Loget 260-TH data displayed on the Elitech iCold mobile application.

  • Datos en tempo real: View live temperature, humidity, light, shock, and location data on the Elitech iCold APP or web plataforma.
  • Datos históricos: Access and analyze historical data, generate reports (PDF/CSV), and track routes through the iCold platform.
  • Notificacións de alarma: Receive instant alerts via APP, SMS, or Email when configured parameters exceed set thresholds. The device also provides local visual and audible alarms.
Elitech Loget 260-TH Data Logger with a laptop showing PDF and CSV report export options from the iCold platform

Figure 4.3: Elitech iCold platform demonstrating PDF and CSV report export functionality.

5. Mantemento

5.1. Coidado da batería

  • Recharge the device regularly, especially if it will be stored for an extended period.
  • Avoid exposing the device to extreme temperatures during charging or storage, as this can degrade battery life.

5.2. Limpeza

  • Limpa o dispositivo cun pano suave e seco.
  • Non empregue produtos de limpeza abrasivos nin solventes, xa que poden danar o casing or sensors.

5.3. Almacenamento

  • Garda o dispositivo nun lugar fresco e seco lonxe da luz solar directa.
  • Asegúrate de que a batería estea parcialmente cargada (arredor do 50 %) antes de almacenala a longo prazo.

6 Solución de problemas

6.1. O dispositivo non se acende

  • Asegúrate de que o dispositivo estea completamente cargado. Conéctao a unha fonte de alimentación mediante o cable USB tipo C.
  • Verify that the 'Start/Stop' button is pressed and held for the required duration.

6.2. No 4G Network Connection

  • Check the signal strength indicator on the LCD. If weak, move to an area with better network coverage.
  • Ensure airplane mode is not active.
  • Contact Elitech support if the issue persists, as the built-in SIM card may require troubleshooting.

6.3. Data Not Uploading to iCold Platform

  • Confirm the device has a stable 4G connection.
  • Verify that the device is correctly added and configured in your iCold account.
  • Check the upload interval settings in the iCold platform.

6.4. Lecturas inexactas

  • Ensure the sensors are not obstructed or exposed to direct heat/cold sources that do not reflect the ambient environment.
  • Allow the device to stabilize in a new environment for a few minutes before taking critical readings.

7. Especificacións

ParámetroValor
Número de modeloUS-LogEt260-TH-10PACK
Temperature Range (Internal)-30 ℃ a 60 ℃ (-22 ℉ a 140 ℉)
Humidity Range (Internal)0% a 100% RH
Rango do sensor de luz0 a 52000 lux
Shock Sensor Range0 g a 16 g
Seguimento da localizaciónLBS (Location-Based Service)
Capacidade de almacenamento de datos100,000 points (offline)
Conectividade4G (Built-in SIM Card)
Intervalo de cargaConfigurable (1 minute to 24 hours)
Tipo de bateríaIon de litio (incluído)
InterfaceUSB tipo C
CumprimentoDo160 (Aviation Safety), FDA CFR 21 Part 11

8. Garantía e soporte

For warranty information, technical support, or service inquiries, please contact Elitech Technology Inc. directly. Refer to the official Elitech websitio web ou a información de contacto proporcionada coa súa compra para obter os detalles de asistencia máis actualizados.

Plataforma Elitech iCold: http://new.i-elitech.com

Documentos relacionados - Loget 260-TH

Preview Manual de instrucións da serie Elitech LogEt 260: rexistradores de datos de temperatura, luz e vibración
Manual de instrucións completo para os rexistradores de datos da serie Elitech LogEt 260, que abrangue a seguridade, as características do produto, a selección, os parámetros técnicos, o funcionamento e os indicadores LED. Inclúe monitorización de temperatura, luz e vibracións e conectividade 4G.
Preview Manual do usuario do rexistrador de datos Elitech LogEt serie 8: monitorización de temperatura e humidade
Manual de usuario completo para os rexistradores de datos Elitech LogEt da serie 8, que detalla as especificacións, o funcionamento, a instalación e a resolución de problemas para a monitorización da temperatura e a humidade na loxística da cadea de frío.
Preview Manual do usuario da serie Elitech LogEt 5: Rexistradores de datos de temperatura e humidade
Manual de usuario completo para os rexistradores de datos de temperatura e humidade da serie Elitech LogEt 5. Abarca máis deview, selección de modelo, especificacións, funcionamento, indicación de estado, substitución da batería e configuracións predeterminadas.
Preview Manual do usuario da serie Elitech LogEt 1: Rexistradores de datos de temperatura e humidade
Manual de usuario completo para a serie Elitech LogEt 1 de rexistradores de datos dun só uso, que abrangue LogEt 1 (temperatura), LogEt 1TH (temperatura-humidade) e LogEt 1 Bio (temperatura de alta precisión). Inclúe especificacións, funcionamento, indicación de estado e avisos.
Preview Manual do usuario do rexistrador de datos de uso único en formato PDF da serie LogEt 1 de Elitech
Manual do usuario para os rexistradores de datos PDF de uso único Elitech LogEt 1, LogEt 1TH e LogEt 1Bio, que abrangue a aparencia, as especificacións técnicas, as instrucións de indicación e o funcionamento.
Preview Especificacións e manual de usuario do rexistrador de datos da serie LogEt 5 de Elitech
Especificacións, características e instrucións de funcionamento completas para a serie Elitech LogEt 5 de rexistradores de datos de temperatura e humidade, deseñados para a monitorización da cadea de frío.