This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

2. Información de seguridade

Instrucións de seguridade importantes:

3. Produto rematadoview e Características

The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.

Características principais:

Compoñentes incluídos:

The complete system includes the following components:

ACiQ 4 Ton Central Air Conditioner System components

Figura 3.1: Acabadoview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

ACiQ Split System Installation Kit components

Figura 3.2: Detallado view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

ACiQ Air Conditioner Condenser Unit Features

Figura 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.

4. Configuración e instalación

Instalación profesional necesaria: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.

The installation process typically involves:

  1. Selección do sitio: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
  2. Unidades de montaxe: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
  3. Refrigerant Line Connection: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
  4. Cableado eléctrico: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
  5. Drenaxe de condensados: Installing proper drainage for the indoor evaporator coil.
  6. Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
  7. Instalación de termostato: Wiring and configuring the Smart WiFi Thermostat.
  8. Proba do sistema: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.

Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.

5. Instrucións de funcionamento

Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.

Smart WiFi Thermostat Operation:

The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:

Smart WiFi Thermostat features and interface

Figura 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.

For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.

6. Mantemento

Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.

Mantemento do usuario (mensual/trimestral):

Professional Maintenance (Annually):

It is highly recommended to schedule annual maintenance with a qualified HVAC technician. This typically includes:

7 Solución de problemas

Antes de contactar cun técnico de servizo, review the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.

ProblemaCausa posibleSolución
System Not Cooling
  • Termostato configurado incorrectamente
  • Filtro de aire sucio
  • Outdoor unit obstructed
  • Problema de alimentación
  • Refrigerant leak (system alert)
  • Check thermostat settings (mode, temperature).
  • Limpar ou substituír o filtro de aire.
  • Clear debris from outdoor unit.
  • Check circuit breaker; ensure disconnect switch is ON.
  • Contacte cun técnico cualificado para a súa inspección e reparación.
Fluxo de aire débil
  • Filtro de aire sucio
  • Blocked return air vents
  • Problemas de canalización
  • Limpar ou substituír o filtro de aire.
  • Ensure all return air vents are open and unobstructed.
  • Consult a technician to inspect ductwork.
Ruídos pouco comúns
  • Pezas soltas
  • Residuos no ventilador
  • Problemas motores
  • Turn off unit and inspect for loose panels or debris.
  • If noise persists or is severe, contact a technician.
Water Leakage (Indoor Unit)
  • Clogged condensate drain line
  • Frozen evaporator coil
  • Clear the condensate drain line.
  • Turn off cooling and allow coil to defrost; check airflow and refrigerant levels. Contact technician if problem persists.

If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.

8. Especificacións

Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:

EspecificaciónValor
MarcaACiQ
Números de modeloACiQ-48-AC / ACIQ-60-ACL / IKIC51
Capacidade4 Tons (48,000 BTU/h)
Eficiencia (SEER2)15.5 SEER2
Tipo de refrixeranteR410A
Voltage230 voltios
Wattage4000 vatios
Nivel de ruído56 dB
Dimensións da unidade exterior (P x L x H)16.14" x 37.24" x 52.48"
Indoor Coil Dimensions (W x D x H)24.49" x 20.98" x 27.99" (622 x 533 x 711 mm)
Tipo de instalaciónSistema dividido
Factor de formaCentral Split System
Tipo de filtroWashable, Reusable Mesh Filter
Cobertura da superficie do pisoAproximadamente 2400 pés cadrados
Características especiaisInverter Unit, Smart Sensors, Gold Fin Coil, Ultra-Quiet, All-Climate Performance
Dimensions of ACiQ outdoor condenser and indoor evaporator coil

Figura 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Specifications for ACiQ evaporator coil

Figura 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

AHRI Rating Conditions and EnergyGuide label for ACiQ system

Figura 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.

9. Garantía e soporte

Condicións da garantía: The ACiQ system comes with a Garantía de pezas de 7 anos e a 12 anos de garantía do compresor. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.

Atención ao cliente: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official websitio web ou a documentación incluída coa túa compra. Tamén podes visitar o ACiQ Store on Amazon para máis información.

Documentos relacionados - ACiQ-48-AC

Preview Manual de instalación da unidade exterior dos sistemas de inversores centrais ACiQ
Manual de instalación completo para as unidades exteriores dos sistemas de inversores centrais ACiQ, que abrangue as precaucións de seguridade, as tubaxes de refrixerante, a instalación da unidade exterior, o cableado, as especificacións de alimentación, a evacuación do aire e os procedementos de proba de funcionamento. Inclúe detalles do modelo e notas importantes para unha configuración correcta.
Preview ACiQ Central Inverter Systems Installation Manual
Comprehensive installation manual for ACiQ Central Inverter Air Conditioning and Heat Pump Systems, detailing safety precautions, refrigerant piping, outdoor unit installation, wiring, power specifications, air evacuation, and test run procedures.
Preview Manual de instalación da unidade exterior dos sistemas de inversores centrais ACiQ
Manual de instalación completo para as unidades exteriores dos sistemas de inversores centrais ACiQ, que abrangue as precaucións de seguridade, as tubaxes de refrixerante, o cableado, a instalación da unidade e os procedementos de proba para modelos como ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB e outros.
Preview Guía técnica de vendas de controladores de aire unitarios e condensadores de bomba de calor ACiQ R32
Esta guía técnica de vendas proporciona especificacións detalladas, datos de rendemento, dimensións e diagramas de cableado para a serie de controladores de aire unitarios e condensadores de bomba de calor ACiQ R32, que abrangue os modelos ACiQ-24/36/48/60-AH32 e ACiQ-24/36/48/60-HP32.
Preview Manual de instalación do controlador de aire por condutos ACiQ (12K-60K BTU/h)
Este manual de instalación de ACiQ ofrece instrucións detalladas para a instalación segura e correcta de unidades de tratamento de aire por condutos, modelos de 12 000 a 60 000 BTU/h. Abarca as directrices de seguridade esenciais, a colocación das unidades, as tubaxes de refrixerante, o cableado eléctrico, as especificacións e as probas de funcionamento para garantir un rendemento óptimo e unha lonxevidade do sistema.
Preview Guía de inicio rápido do sistema de bomba de calor por condutos ACiQ de próxima xeración
Guía de inicio rápido para o sistema de bomba de calor por condutos ACiQ de próxima xeración, que abrangue diagramas de cableado, conexións do termostato e configuración do interruptor DIP para varios escenarios de instalación.