1. Introdución
This instruction manual provides essential information for the safe and effective use of the GODIYMODULES Multi-Cell Lithium-ion Battery Management System (BMS) Module. This module is designed to protect lithium-ion battery packs ranging from 6 series (6S) to 13 series (13S) configurations, ensuring their longevity and safe operation by managing charging, discharging, and various protection functions.
The BMS module integrates features such as overcharge, over-discharge, overcurrent, and temperature protection, which are crucial for the stability and safety of high-energy density lithium-ion battery packs.
2. Información de seguridade
WARNING: Working with lithium-ion batteries and high-current circuits can be dangerous. Incorrect wiring or handling can lead to fire, explosion, or severe injury. Always exercise extreme caution.
- Asegúrese de que todas as conexións estean correctas e seguras antes de aplicar a alimentación.
- Verify battery cell voltages and polarities before connecting to the BMS.
- Do not short-circuit the battery pack or the BMS terminals.
- Use appropriate personal protective equipment (PPE) such as safety glasses and insulated tools.
- If you are unsure about any step, seek assistance from a qualified professional.
- Keep the BMS module away from moisture and extreme temperatures.
3. Produto rematadoview
The GODIYMODULES BMS module is a compact circuit board designed for robust battery protection. It features multiple MOSFETs for power handling and a dedicated IC for cell voltage monitoring. The board supports a wide range of series configurations, making it versatile for various battery projects.

Figura 3.1: Arriba view of the GODIYMODULES BMS module with its included wiring harness.

Imaxe 3.2: Primeiro plano view of the BMS circuit board, showing components and connection points.
Características principais:
- Supports 6S to 13S Li-ion battery configurations.
- Overcharge protection with a detection voltage of approximately 3.75V per cell.
- Over-discharge protection with a detection voltage of approximately 2.1V per cell.
- Overcurrent protection for both discharge (up to 66A peak) and charge (18A continuous).
- Temperature protection with a control interface.
- Low quiescent current (25µA).
4. Especificacións
Below are the detailed technical specifications for the GODIYMODULES BMS module. Please note that typical values are provided, and slight variations may occur.

Figure 4.1: Detailed specifications for protection items, including voltage e os limiares actuais.

Figure 4.2: Detailed specifications for continuous discharge/charge current and quiescent current.
| Parámetro | Min | Típico | Máx | Unidade |
|---|---|---|---|---|
| Over-charge Detection Voltage | 3.725 | 3.75 | 3.775 | V |
| Recuperación de sobrecarga voltage | 3.55 | 3.6 | 3.65 | V |
| Over-charge Protection Delay Time | 700 | 1000 | 1300 | ms |
| Over-discharge Detection Voltage | 2.05 | 2.1 | 2.15 | V |
| Recuperación por sobredescarga voltage | 2.25 | 2.3 | 2.35 | V |
| Over-discharge Protection Delay Time | 105 | 140 | 175 | ms |
| Over-discharge Protection Current | 54 | 60 | 66 | A |
| Common-port Discharge Current (Continuous) | 18 | A | ||
| Over-discharge Current Protection Delay Time | 18 | 24 | 30 | ms |
| Protección contra sobrecarga de corrente | 32 | 40 | 48 | A |
| Charging Current (Continuous) | 18 | A | ||
| Over-charge Current Protection Delay Time | 12 | 16 | 20 | ms |
| Corrente Quiescente | 25 | µA | ||
| Protección de temperatura | Yes, with Temperature Control Interface | |||
| Protección contra sobrecorriente | Cut off the load | |||
| Protección contra curtocircuítos | Disconnect Load to Release | |||
| Balancing Function | Ningún | |||
| Dimensións do corpo | 55.13 x 31.57 x 6 mm (aprox.) | |||
| Vol. De saídatage (Nominal per cell) | 4.2 Volts (Charging termination voltage) | |||
| Corrente de descarga continua | 18 Amps | |||
| Corrente de carga continua | 18 Amps | |||
| Tipo de conector | XT60 (for main power, general recommendation) | |||
Note on Voltage Discrepancia: The product title mentions "4.2V Lithium Li-ion Battery". This typically refers to the nominal maximum charging voltage per cell for standard Li-ion batteries. The "Over-charge Detection Voltage" of 3.75V (typical) refers to the voltage threshold at which the BMS initiates overcharge protection for an individual cell. The BMS is designed for 4.2V cells.
Note on Current Rating: The product title mentions "25A", while specifications list "Common-port Discharge Current (Continuous): 18A" and "Over-discharge Protection Current: 60A (peak)". The continuous discharge and charge current is 18A. The 25A likely refers to a maximum instantaneous or burst current, or a different model variant. For sustained operation, adhere to the 18A continuous rating.

Figure 4.3: Dimensional drawing of the BMS module, showing key measurements in millimeters.
5. Configuración e instalación
Careful wiring is critical for the correct and safe operation of the BMS. Follow these instructions precisely.

Figura 5.1: Example wiring diagram for a 7S battery pack. The principle applies to 6S-13S configurations.
Pasos de cableado:
- Prepare Battery Pack: Ensure all individual cells in your battery pack are balanced (have similar voltages) before connecting to the BMS. This is crucial for optimal performance and safety, especially since this BMS does not have an active balancing function.
- Connect Main Negative (B-): Connect the thickest negative wire from the BMS (labeled B-) to the main negative terminal of your entire battery pack (the negative terminal of the first cell).
- Connect Balance Leads:
- The BMS comes with a multi-pin connector and thin wires (balance leads). These wires must be connected to the positive terminals of each individual cell, starting from the first cell's positive terminal (which is also the negative of the second cell).
- Connect the first balance lead (often labeled B1 or the lowest numbered wire) to the positive terminal of the first cell (Cell 1+).
- Connect the second balance lead (B2) to the positive terminal of the second cell (Cell 2+), and so on.
- The highest numbered balance lead (e.g., B13 for a 13S pack) connects to the main positive terminal of the entire battery pack (Cell 13+).
- Importante: Connect the balance leads in ascending order of cell voltage. Incorrect order can damage the BMS.
- For fewer than 13S: If your battery pack has fewer than 13 cells (e.g., 7S), connect the unused higher-numbered balance leads (e.g., B8 through B13 for a 7S pack) to the same point as the highest active balance lead (B7+ in a 7S example). This effectively bridges them to the pack's positive terminal.
- Connect Load Negative (P-): Connect the negative terminal of your load (e.g., motor controller, inverter) to the P- terminal on the BMS.
- Connect Charger Negative (C-): Connect the negative terminal of your battery charger to the C- terminal on the BMS.
- Main Positive Connection: The main positive terminal of the battery pack (Cell N+, where N is your series count) is typically connected directly to the positive terminals of both the load and the charger, bypassing the BMS for the positive path. This is a common-port BMS design.
Always double-check all connections with a multimeter before applying power. Verify that the voltage across each balance lead corresponds to the correct cell voltage.
6. Principios de funcionamento
The GODIYMODULES BMS continuously monitors the voltage of each individual cell within the battery pack, as well as the overall current flowing in and out of the pack. When any monitored parameter exceeds or falls below its predefined safe threshold, the BMS will activate its protection mechanisms.
- Protección de sobrecarga: Se algunha célula voltage rises above the overcharge detection voltage (e.g., 3.75V), the BMS will cut off the charging current to prevent cell damage. Charging will resume once the cell voltage drops to the recovery voltage.
- Protección contra descarga excesiva: Se algunha célula voltage drops below the over-discharge detection voltage (e.g., 2.1V), the BMS will cut off the discharge current to prevent irreversible cell damage. Discharge will resume once the cell voltage rises to the recovery voltage (typically by applying a charge).
- Protección contra sobrecorriente: If the discharge or charge current exceeds the specified limits (e.g., 18A continuous, 60A peak discharge protection), the BMS will temporarily cut off the current to protect the battery and the BMS itself. This protection typically recovers automatically once the overload is removed.
- Protección de temperatura: The BMS monitors its own temperature or an external thermistor (if connected). If the temperature exceeds safe operating limits, it will cut off charge/discharge to prevent thermal runaway.
7 Solución de problemas
If you encounter issues with your BMS module, consider the following troubleshooting steps:
- No Output Power / BMS Not Functioning:
- Verify all wiring connections, especially the main B-, P-, C- terminals, and all balance leads. A single incorrect balance lead connection can prevent the BMS from operating.
- Consulta o voltage of each individual cell. If any cell is significantly overcharged or under-discharged, the BMS may be in a protected state.
- Ensure the main battery pack voltage is within the operational range for your series configuration.
- BMS Cuts Off Power Prematurely:
- Sobreintensidade: The load might be drawing more current than the BMS's continuous or peak rating. Reduce the load or ensure your application's current draw is within limits.
- Sobrecarga: One or more cells might be reaching their low voltage threshold faster than others, indicating an unbalanced pack or a faulty cell. Check individual cell voltages.
- Temperatura: The BMS or battery pack might be overheating. Ensure adequate ventilation.
- A batería non se carga:
- Verify the charger is connected correctly to C- and the main positive.
- Check if any cells are in an overcharged state, triggering overcharge protection.
- Asegúrate do volume do cargadortage and current output are compatible with your battery pack and BMS.
If issues persist after troubleshooting, contact the manufacturer for further assistance.
8. Mantemento
The GODIYMODULES BMS module is designed for reliable operation with minimal maintenance. However, following these guidelines can help ensure its longevity:
- Mantéñase limpo e seco: Protect the BMS from dust, dirt, and moisture. Do not expose it to water or corrosive substances.
- Inspeccionar conexións: Periodically check all wiring connections for tightness and signs of corrosion or damage. Loose connections can lead to poor performance or safety hazards.
- Ventilación: Ensure the BMS and battery pack have adequate ventilation, especially during high-current operation, to prevent overheating.
- Evitar danos físicos: Handle the board carefully to prevent physical damage to components or solder joints.
9. Garantía e soporte