ZIBOO 15B PRO

ZIBOO 15B PRO True RMS Digital Multimeter User Manual

Model: 15B PRO

1. Información de seguridade

Before using the ZIBOO 15B PRO Digital Multimeter, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or personal injury.

1.1 Directrices xerais de seguridade

  • Asegúrese sempre de que o multímetro estea na función e no rango correctos antes de realizar medicións.
  • Non empregue o multímetro se parece estar danado ou se os cables de proba están comprometidos.
  • Observe all safety precautions for working with electricity, including wearing appropriate personal protective equipment (PPE).
  • Never exceed the maximum input values for any function.
  • The device is rated CAT III 600V and CAT II 1000V. Adhere to these ratings for safe operation.
  • The multimeter features double fuse protection to prevent damage from overload.

2. Produto rematadoview

The ZIBOO 15B PRO True RMS Digital Multimeter is a compact and reliable tool designed for a wide range of electrical testing applications. It offers accurate measurements for AC/DC voltage, AC/DC current, resistance, continuity, diode, capacitance, and duty cycle. Its True RMS capability ensures precise readings for non-sinusoidal waveforms.

ZIBOO 15B PRO Digital Multimeter front view

Figura 1: Fronte view of the ZIBOO 15B PRO Digital Multimeter, showing the display, rotary dial, and function buttons.

2.1 Características principais

  • RMS verdadeiro: Provides accurate measurements for both sinusoidal and non-sinusoidal AC waveforms.
  • Visualización de 6000 contas: High-resolution display for precise readings.
  • AC / DC Voltage: Mide ata 1000 V.
  • Corrente CA/CC: Measures up to 10A (optional current clamp for up to 600A).
  • Resistance, Continuity, Diode, Capacitance, Duty Cycle: Essential functions for comprehensive electrical troubleshooting.
  • VFD AC 600V: Variable Frequency Drive measurement capability.
  • NCV/LIVE: Vol. Sen contactotage and Live Wire Detection with Red LED Flash.
  • Retención de datos: Freezes the displayed reading for easier recording.
  • Retroiluminación: Bright white backlight for clear visibility in various lighting conditions.
  • C protectorasing: C exterior duradeiroasing for enhanced protection.
Icons representing various functions of the ZIBOO 15B PRO multimeter

Figure 2: Visual representation of the various measurement functions available on the multimeter.

2.2 Que hai na caixa

  • ZIBOO 15B PRO Digital Multimeter
  • Multimeter Test Leads (Red and Black)
  • Protective Caps for Test Leads
  • Manual de usuario

Note: AC pliers are an optional accessory and are not included with the standard package.

3. Configuración

3.1 Instalación da batería

  1. Asegúrate de que o multímetro estea apagado.
  2. Localice o compartimento da batería na parte traseira do dispositivo.
  3. Unscrew the single Phillips #1 screw to open the compartment.
  4. Insert three AA 1.5V batteries, observing correct polarity.
  5. Coloque a tapa do compartimento da batería e fíxaa co parafuso.

3.2 Conexión dos cables de proba

  1. Insira a punta de proba negra na toma "COM" (común).
  2. Para a maioría das medicións (voltage, resistance, continuity, diode, capacitance, frequency, duty cycle), insert the red test lead into the 'VΩHz' jack.
  3. For current measurements up to 10A, insert the red test lead into the '10A' jack.
  4. Para miliampere (mA) ou microampere (µA) measurements, insert the red test lead into the 'µAmA' jack.
ZIBOO 15B PRO Digital Multimeter with red and black test leads connected

Figure 3: The ZIBOO 15B PRO Multimeter with its test leads, showing the connection points.

4. Instrucións de funcionamento

4.1 Acendido/apagado e visualización

Turn the rotary dial from 'OFF' to any desired function to power on the multimeter. To power off, turn the dial back to 'OFF'. The device features an automatic power-off function to conserve battery life. Press the LED button to activate or deactivate the display backlight for improved visibility.

4.2 Funcións de medición

Rotate the dial to select the desired measurement function. Use the MODO button to toggle between different sub-functions within a dial position (e.g., AC/DC voltage, NCV/LIVE).

  1. VoltagMedición (CA/CC):
    Set the dial to 'V~' for AC voltage or 'V=' for DC voltage. Connect the test leads in parallel to the circuit or component being measured. The display will show the voltage lectura.
  2. Medición de corrente (CA/CC):
    Set the dial to 'A~' for AC current or 'A=' for DC current. Ensure the red test lead is in the appropriate current jack (10A or µAmA). Connect the multimeter in series with the circuit.
  3. Medición da resistencia (Ω):
    Set the dial to 'Ω'. Connect the test leads across the component. Ensure the circuit is de-energized before measuring resistance.
  4. Proba de continuidade (Icona de continuidade):
    Set the dial to 'Ω' and press MODO until the continuity icon appears. A buzzer will sound and a green LED will flash if continuity is detected (low resistance).
  5. Proba de diodos (Icona do diodo):
    Set the dial to 'Ω' and press MODO until the diode icon appears. Connect the test leads across the diode.
  6. Medición de capacitancia (F):
    Set the dial to 'F'. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.
  7. NCV (Non-Contact Voltage) / LIVE (Live Wire Detection):
    Set the dial to 'NCV LIVE'. The multimeter will detect AC voltage without direct contact. 'L' indicates a live wire with voltage, accompanied by a red LED flash and buzzer. 'EF' indicates non-contact detection.
ZIBOO 15B PRO Multimeter demonstrating NCV function near an electrical outlet

Figure 4: The multimeter's NCV function detecting voltage near an electrical outlet, indicated by 'EF' on the display.

Video 1: This video demonstrates the difference between the NCV (Non-Contact Voltage) and LIVE (Live Wire Detection) functions on the ZIBOO 15B PRO/17B PRO multimeters. It shows how to toggle between these modes and their respective indications when detecting live electrical circuits.

4.3 Funcións especiais

  • MANTENER: Preme o ATENCIÓN botón para conxelar a lectura actual na pantalla. Prema de novo para soltala.
  • MIN / MAX: Preme o MIN / MAX button to record the minimum and maximum values during a measurement session. Press again to cycle through MIN, MAX, and current readings.
  • GAMA: Preme o GAMA button to switch between auto-ranging and manual ranging.

5. Mantemento

5.1 Limpeza

Limpar o multímetro casing con anuncioamp un pano e un deterxente suave. Non empregue produtos de limpeza abrasivos nin disolventes. Asegúrese de que o dispositivo estea completamente seco antes de usalo.

5.2 Substitución da batería

When the battery indicator appears on the display, replace the batteries as described in Section 3.1. Always use three new AA 1.5V batteries.

5.3 Substitución de fusibles

The multimeter is equipped with internal fuses for protection. If a current measurement function stops working, the fuse may need replacement. To access the fuses, open the battery compartment (Section 3.1). The fuses are located inside. Replace with fuses of the correct type and rating (e.g., 10A/1000V and 500mA/1000V).

Interno view of the ZIBOO 15B PRO multimeter showing the double fuse protection

Figura 5: Interno view highlighting the double fuse protection for safety and durability.

5.4 Test Lead Care

The test leads come with protective caps. Use these caps to protect the sharp tips when not in use or when measuring in situations where only a short tip is required. This helps prevent damage to the probes and ensures safety.

6 Solución de problemas

If you encounter issues with your ZIBOO 15B PRO Digital Multimeter, refer to the following common troubleshooting steps:

  • Sen pantalla/Pantalla tenue: Check battery levels and replace if necessary. Ensure the multimeter is powered on.
  • Lecturas incorrectas: Verify the test leads are correctly inserted into the appropriate jacks for the selected function. Ensure the rotary dial is set to the correct measurement type and range. Check for damaged test leads.
  • Current Function Not Working: The internal fuse for current measurement may have blown due to an overload. Replace the fuse as described in Section 5.3.
  • O zumbador de continuidade non soa: Ensure the multimeter is in continuity mode. Check for open circuits or high resistance.

For persistent issues, consult the manufacturer's support resources.

7. Especificacións

CaracterísticaEspecificación
Mostrar6000 Counts, True RMS
DC Voltage (V)6V/60V/600V/1000V (±(0.5%+3))
Vol. ACtage (V)6V/60V/600V/1000V (±(0.8%+5))
VFD AC Voltage (V)600V (±(0.8%+5))
Corrente DC (A)600µA/6mA/60mA/600mA/6A/10A (±(0.8%+5) to ±(1.5%+5))
Corrente CA (A)600µA/6mA/60mA/600mA/6A/10A (±(1.0%+5) to ±(1.8%+5))
Resistencia (Ω)600Ω/6KΩ/60KΩ/600KΩ/6MΩ/60MΩ (±(0.8%+5) to ±(2.5%+5))
Capacitancia (F)60nF-60mF (±(3%+5) to ±(5%+5))
Frecuencia (Hz)10Hz-20MHz (±(0.1%+5))
Ciclo de traballo10%-90% (±(2%+5))
Valoración de seguridadeCAT III 600V, CAT II 1000V
Fonte de enerxía3 x AA 1.5V Batteries
Dimensións do produto3.58 x 1.77 x 7.2 polgadas
Peso do produto1.19 libras (402 g)

Note: Accuracy specifications are typical values and may vary slightly.

Detailed specifications table for ZIBOO 15B PRO and 17B PRO multimeters

Figure 6: A detailed table outlining the technical specifications for the ZIBOO 15B PRO multimeter.

8. Garantía e soporte

For warranty information and customer support, please refer to the official ZIBOO website or contact the seller directly through the platform where the product was purchased. Standard return policies typically apply (e.g., 30-day return window).

Documentos relacionados - 15B PRO

Preview User Manual: Earth Clamp Tester (Model UT278A)
Comprehensive user manual for the ZIBOO Earth Clamp Tester, detailing safety precautions, technical specifications, operation methods, and field applications for measuring grounding resistance. Includes instructions for multi-point, limited-point, and single-point grounding systems.
Preview ZIBOO DC Resistance Tester UT620C User Manual
User manual for the ZIBOO DC Resistance Tester (Model UT620C), detailing safety precautions, technical specifications, operation, and accessories for measuring low DC resistance.
Preview ZIBOO FT-1000W/FT-2000W Solar MPPT Power Meter User Manual & Specifications
User manual and technical specifications for ZIBOO FT-1000W and FT-2000W Solar MPPT Power Meters, covering safety precautions, general specifications, operation, and maintenance.
Preview Metravi Pro Uniks C128 1000A TRMS AC/DC Clamp Medidor - Especificacións técnicas
Especificacións e características detalladas do Metravi Pro Uniks C128 1000A TRMS AC/DC Clamp Meter, designed for industrial and civil use with advanced measurement capabilities including TRMS, NCV, and VFD filtering.
Preview Multicomp PRO MP730026 Digital Multimeter User Manual
Comprehensive user manual for the Multicomp PRO MP730026 Digital Multimeter. Covers safety precautions, quick start guide, detailed measurement procedures for voltage, current, resistance, capacitance, frequency, temperature, non-contact voltage detection, and transistor testing. Includes information on multimeter features like data hold and relative measurements, buzzer functions, technical specifications, standard accessories, and general care and cleaning instructions.
Preview Proster CM6000 Pro Digital AC/DC Clamp Manual do usuario do contador
Manual de usuario completo para o Proster CM6000 Pro Digital AC/DC Clamp Medidor, detallando as súas características, especificacións, funcionamento, precaucións de seguridade e resolución de problemas. Abarca medicións de CC, CC, CC, CCA, resistencia, capacitancia, frecuencia, temperatura, díodo, continuidade e CC.