SUNLAB Q-214-QUARTZ CELL-09

SUNLAB Q-214 Fused Quartz Fluorescence Cuvette User Manual

Model: Q-214-QUARTZ CELL-09

Introdución

This manual provides essential instructions for the proper use, handling, and maintenance of the SUNLAB Q-214 Fused Quartz Fluorescence Cuvette. Designed for laboratory use, this cuvette is suitable for various spectroscopic applications, including spectrophotometry, fluorometry, tintometry, colorimetry, polarimetry, and other laser applications. Its high-purity quartz construction ensures chemical resistance and high transparency across UV and visible light spectra.

SUNLAB Q-214 Fused Quartz Fluorescence Cuvette packaging

Descrición da imaxe: The product packaging for the LABSOUL Q-214 Fused Quartz Cuvette. The box indicates "For Laboratory use" and lists specifications such as volume (3.5ml), path length (10mm), and dimensions (45x12.5x12.5mm). A certificate of conformity is also visible, indicating quality assurance.

Características do produto

Two SUNLAB Q-214 Fused Quartz Cuvettes in a protective case

Descrición da imaxe: Two SUNLAB Q-214 Fused Quartz Cuvettes are shown inside a protective black case, each with a Teflon stopper. A transmission certificate is visible, indicating the percentage transmission at various wavelengths (200nm, 220nm, 240nm).

Configuración e preparación

  1. Desembalaxe: Carefully remove the cuvette from its protective packaging. Inspect for any visible damage.
  2. Limpeza inicial: Before first use, clean the cuvette thoroughly. Use a mild detergent solution specifically designed for laboratory glassware, followed by rinsing with deionized water. Avoid abrasive materials.
  3. Secado: Allow the cuvette to air dry or use a lint-free cloth to gently dry the exterior. Ensure no fibers remain on the optical surfaces.
  4. Manexo: Always handle the cuvette by its frosted sides to prevent fingerprints or oils from contaminating the polished optical surfaces. Fingerprints can interfere with light transmission and affect measurement accuracy.

Instrucións de funcionamento

The Q-214 Fused Quartz Fluorescence Cuvette is designed for precise measurements in various analytical instruments.

Uso xeral

  1. Sample Filling: Fill the cuvette with your sample solution, ensuring the liquid level is above the light path but below the top edge to prevent spillage. The 3.5ml volume is designed for optimal performance.
  2. Selado: If required, securely insert the Teflon stopper to prevent evaporation or contamination.
  3. Placement in Instrument: Carefully place the cuvette into the spectrophotometer, fluorometer, or other analytical instrument. Ensure the polished optical windows are aligned correctly with the instrument's light path.
  4. Medición: Follow the specific operating procedures of your analytical instrument to perform measurements.
  5. Eliminación: After measurement, carefully remove the cuvette, holding it by the frosted sides.
Hand in glove placing a cuvette into a spectrophotometer

Descrición da imaxe: A gloved hand is shown carefully placing a cuvette, containing a yellow liquid sample, into the sample compartment of a laboratory spectrophotometer. This illustrates the proper handling and placement of the cuvette during operation.

Aplicacións

This cuvette is suitable for a wide range of laboratory applications:

Infographic showing Quartz Cuvette Applications

Descrición da imaxe: An infographic titled "QUARTZ CUVETTE APPLICATIONS" illustrating various uses. These include Spectrophotometry, DNA/RNA Analysis, Chemical Kinetics, and Protein Quantification, each with a brief description of its relevance to cuvette use.

Infographic showing Quartz Cuvette Uses

Descrición da imaxe: An infographic titled "QUARTZ CUVETTE USES" displaying four hexagonal icons representing different applications: UV-Visible (UV-Vis) Spectroscopy, Fluorescence Spectroscopy, Fourier-Transform Infrared (FTIR) Spectroscopy, and Biomedical Research.

Mantemento e coidados

  1. Limpeza despois do uso: Immediately after use, empty the cuvette and rinse it thoroughly with an appropriate solvent (e.g., deionized water, ethanol, or specific cleaning solutions depending on the sample).
  2. Limpeza profunda: For stubborn residues, a mild acid (e.g., 10% HCl) or a specialized cuvette cleaning solution can be used. Always follow the manufacturer's instructions for cleaning agents. Rinse extensively with deionized water afterwards.
  3. Secado: Air dry the cuvette in a dust-free environment or use a gentle stream of clean, dry air or nitrogen. Avoid wiping the optical surfaces with anything other than specialized lint-free optical wipes.
  4. Almacenamento: Store the clean, dry cuvette in its protective case or a dedicated cuvette rack to prevent scratches and contamination. Keep it away from dust and direct sunlight.
  5. Avoid Extreme Shock: As indicated on the packaging, avoid extreme shock or dropping the cuvette, as this can result in product failure.
Lado view of LABSOUL cuvette packaging with safety warning

Descrición da imaxe: Un lado view of the LABSOUL cuvette packaging. Text on the side reads "SAFETY IS PART OF SCIENCE" and includes a warning: "Avoid shock while transporting and handling the box. Extreme shock such as dropping the box can result in product failure." This emphasizes the importance of careful handling.

Resolución de problemas

Especificacións

AtributoValor
MarcaSUNLAB
Número de modeloQ-214-QUARTZ CELL-09
MaterialFused Quartz
Lonxitude do camiño10 mm
Volume3.5 ml
Dimensións (H x W x D)45 mm x 12.5 mm x 12.5 mm
WindowsFour Polished Windows
Stopper TypeTeflon Stopper
Bottom TypeRound Bottom
ASINB0DVC8HWC1
Data de primeira dispoñibilidade29 de xaneiro de 2025

Garantía e Soporte

For information regarding product warranty, returns, or technical support, please contact your vendor or the manufacturer, SUNLAB. Refer to your purchase documentation for specific warranty terms and contact details.

Manufacturer: LABTRON

Item part number: Q-214-QUARTZ CELL-09

Documentos relacionados - Q-214-QUARTZ CELL-09

Preview SUNLab™ Round Above-Ground Pool User Guide: Installation & Safety
Comprehensive user guide for SUNLab™ round above-ground pools. Learn about safe installation, operation, maintenance, winterization, and replacement parts for Series 3 and Series 5 models.
Preview Paloma Above Ground Pool 18ft 52" Black Box Contents - Sunlab
Detailed box contents for the Sunlab Paloma 18ft 52" above ground pool, including product number 97300018 and a list of components with quantities and part numbers.
Preview Paloma Above Ground Pool 21ft 52" Black Box Contents - Product 97300021
Detailed box contents list for the Sunlab Paloma 21ft 52" Black Above Ground Pool, including component names, quantities, and part numbers. Product ID: 97300021.
Preview Paloma Above Ground Pool 12ft 52" Black Box Contents
Detailed box contents for the Sunlab Paloma 12ft 52" Black Above Ground Pool, including component names, quantities, and part numbers. Product # 97300012.
Preview PIKE Technologies HATR: Maximum Sensitivity and Versatile FTIR Sampling
This document details the PIKE Technologies HATR (Horizontal Attenuated Total Reflectance) accessory for FTIR spectroscopy. It highlights its features for analyzing liquid, semi-liquid, and solid samples with high sensitivity and minimal sample preparation. The document covers in-compartment (HATR) and out-of-compartment (HATRPlus) designs, various crystal plate options (ZnSe, KRS-5, Ge, AMTIR, Si), and accessories like heated and liquid-jacketed plates for temperature control and flow-through applications. Ordering information for complete systems, individual plates, and replacement parts is also provided.
Preview Hellma Analytics TRAYCELL 2.0: Microvolume UV/VIS Measuring Cell for DNA, Protein Analysis
Discover the Hellma Analytics TRAYCELL 2.0, an innovative fiber-optic microvolume measuring cell for precise UV/VIS analysis of DNA, proteins, and micro samples. Features include small sample volumes, accurate path lengths, and broad application range.