Introdución

Welcome to the user manual for the HOCHIKI BHC-4111 Emergency Alarm Composite Device. This manual provides essential information for the safe and effective use of your device. Please read it thoroughly before installation and operation, and keep it for future reference.

Información de seguridade

This section outlines important safety precautions. Failure to follow these instructions may result in property damage, injury, or improper device operation.

  • A instalación só debe ser realizada por persoal cualificado.
  • Do not attempt to modify or repair the device yourself. Contact authorized service personnel.
  • Ensure the power supply meets the device's specifications.
  • Keep the device free from dust, moisture, and extreme temperatures.
  • Regularly inspect the device for any signs of damage or malfunction.

Produto rematadoview

The HOCHIKI BHC-4111 is an emergency alarm composite device designed for exposed installation. It integrates an alarm light, speaker, and activation button for comprehensive emergency notification.

HOCHIKI BHC-4111 Emergency Alarm Composite Device

Descrición da imaxe: A beige rectangular device featuring a prominent red dome-shaped alarm light at the top, a black speaker grille below it, and an orange panel with a push button and text at the bottom. This image illustrates the front view of the HOCHIKI BHC-4111 unit.

Configuración

  1. Desembalaxe: Carefully remove the device from its packaging. Verify all components are present (main unit).
  2. Lugar de montaxe: Select a suitable location for exposed installation, ensuring it is easily accessible and visible in case of an emergency. Avoid areas with excessive vibration, moisture, or direct heat.
  3. Cableado: Connect the device to the appropriate power source and alarm system wiring according to local electrical codes and the detailed wiring diagram provided in the full installation guide (not included in this basic manual). A instalación profesional é moi recomendable.
  4. Encendido inicial: Once wired, apply power to the device. Observe for any indicator lights or initial self-tests.

Instrucións de funcionamento

The BHC-4111 is designed for straightforward operation in emergency situations.

Activando a alarma

In the event of an emergency, press the designated activation button located on the orange panel of the device. This will trigger the alarm light and sound.

Silenciar a alarma

Follow the procedures established by your facility's emergency response plan to silence the alarm. This typically involves resetting the main alarm control panel. Refer to your system's specific instructions.

Luces indicadoras

The device may feature indicator lights to show its status (e.g., power, fault, alarm active). Consult the full installation guide for a detailed explanation of each indicator.

Mantemento

Regular maintenance ensures the reliable operation of your BHC-4111 device.

  • Limpeza: Periodically clean the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Probas funcionais: Conduct periodic functional tests as recommended by local regulations and your facility's safety protocols. This typically involves activating the alarm and verifying its operation.
  • Substitución da batería (se procede): If the device contains backup batteries, ensure they are replaced according to the manufacturer's recommendations.
  • Inspección profesional: Schedule regular inspections and maintenance by qualified technicians to ensure compliance and optimal performance.

Resolución de problemas

Esta sección ofrece pasos básicos para a resolución de problemas comúns. Para problemas complexos, póñase en contacto cun técnico cualificado.

ProblemaCausa posibleSolución
A alarma non se activaNo power; Faulty wiring; Device malfunctionCheck power supply; Verify wiring connections; Contact service technician
A alarma soa continuamenteSystem not reset; Faulty activation buttonReset main alarm panel; Contact service technician
No light/soundPower issue; Component failureCheck power; Contact service technician

Especificacións

  • Marca: HOCHIKI
  • Número de modelo: BHC-4111
  • Dimensións do produto: 6 cm (profundidade) x 14 cm (ancho) x 25.4 cm (altura)
  • Compoñentes incluídos: Unidade principal
  • Fabricante: Hochiki Corporation
  • Tipo: Emergency Alarm Composite Device (Exposed Type)

Garantía e Soporte

For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact Hochiki Corporation directly.

Nota: This manual provides general guidance. Always refer to the official manufacturer's documentation for complete and up-to-date information.

Documentos relacionados - BHC-4111

Preview Instrucións de funcionamento de Hochiki FireNET PLUS para o panel de control FN-1127 e os anunciadores FN-LCD-S
Instrucións de funcionamento completas para o panel de control Hochiki FireNET PLUS FN-1127 e os anunciadores FN-LCD-S, que detallan as condicións de incendio e problemas, as funcións dos botóns, a substitución de fusibles, o mantemento da batería e a liberación SOM-R.asinfunción g.
Preview Dispositivos de alarma contra incendios para citas en Hochiki: unha guía de Fire Trade Supplies
Aprende a datar os dispositivos de alarma contra incendios Hochiki, incluído o modelo ATJ-EN, usando números de serie e códigos de fabricación. Atopa os datos de contacto de Fire Trade Supplies.
Preview Guía de produtos de Hochiki ISS30:MAR24 - Sistemas e solucións de detección de incendios
Guía completa de produtos de Hochiki, que detalla a súa gama avanzada de sistemas de detección de incendios, incluíndo sistemas direccionables, convencionais, inalámbricos e aéreos.amptecnoloxías ling. Coñece o compromiso de Hochiki coa innovación en seguridade contra incendios.
Preview HOCHIKI ACE-V Analog Multi-Criteria Detector - Technical Specifications and Features
Detailed information on the HOCHIKI ACE-V Analog Multi-Criteria Detector, including its applications, standard features, operation, technical specifications, and product listings. Designed for effective smoke and heat detection.
Preview Instrucións de instalación do sistema de interface de evacuación por voz FNV 25 / FNV 50 / FNV 100
Guía de instalación completa para os sistemas de interface de evacuación por voz Hochiki FNV 25, FNV 50 e FNV 100. Abarca todo o sistema.view, installation procedures, wiring details, terminal designations, operation, specifications, switch settings, and troubleshooting.
Preview Hochiki DCP-SOM-AI/DCP-SOM-A Class A Supervised Output Module Installation Instructions
Detailed installation guide for Hochiki America's DCP-SOM-AI and DCP-SOM-A Class A Supervised Output Modules, covering general description, mounting, wiring, specifications, and SCI operation.