1. Introdución
Thank you for choosing the ELEGRP 20A 125V Duplex Receptacle. This product is designed for reliable electrical connections in residential and commercial settings, featuring both Tamper Resistant (TR) and Weather Resistant (WR) capabilities for enhanced safety and durability. This manual provides essential information for safe installation, operation, and maintenance.

Image 1: ELEGRP 20A 125V Duplex Receptacle with Wall Plate. This image shows a glossy black duplex receptacle with a matching wall plate, along with four additional receptacles without plates, illustrating the product's appearance.
2. Información de seguridade
AVISO: Risk of electric shock. Improper installation can result in serious injury or death. Always turn off power at the circuit breaker or fuse box before installation or servicing. If you are unsure about any part of these instructions, consult a qualified electrician.
- Desconecte sempre a alimentación antes de traballar en circuítos eléctricos.
- Empregue só arame de cobre ou revestido de cobre. Non empregue arame de aluminio con este dispositivo.
- Asegúrate de que todas as conexións dos cables estean seguras e debidamente illadas.
- This device is rated for 20A, 125V. Do not exceed these ratings.
- Instalar de acordo con todos os códigos eléctricos nacionais e locais.
3. Contido do paquete
- ELEGRP 20A 125V Duplex Receptacle(s)
- Matching Wall Plate(s) (if included in package variant)
- Parafusos de instalación
4. Características do produto
- Tamper Resistant (TR): Features an internal shutter mechanism that prevents foreign objects from being inserted into the receptacle openings, protecting children from accidental electric shock.
- Resistente ás inclemencias meteorolóxicas (WR): Constructed with corrosion-resistant components, making it suitable for wet and damp locations, meeting 2017 NEC requirements.
- High-Impact Resistant Thermoplastic: The face and back body are made from durable thermoplastic, designed to withstand accidental drops and pressure during installation, ensuring long-term reliability.
- Resistente á chama: The all-thermoplastic body is flame resistant, providing an additional layer of safety.
- Autoconexión a terra: Includes a green grounding screw and a self-grounding clip for automatic grounding in the junction box, enhancing safety by protecting against electrical shock.
- UL & CUL Listed: Designed and tested in accordance with UL498 requirements, ensuring compliance with safety standards.

Image 2: Tamper Resistant and Weather Resistant Features. This image highlights the TR feature with a baby reaching for an outlet and the WR feature with an outlet installed near a washing machine, indicating suitability for various environments.

Image 3: ELEGRP Receptacle Made to Last Features. This graphic illustrates key durability features including Polycarbonate Thermoplastic, Flame and Impact Resistant, Weather Resistance, Tamper Resistant, and Self-Grounding, with an internal view of the receptacle.

Image 4: High-Impact Resistant Receptacle. This image visually represents the high-impact resistance of the receptacle, showing it withstanding force, emphasizing its robust construction.
5. Instalación
5.1 Lista de comprobación previa á instalación
- Desconecte o interruptor automático ou a caixa de fusibles.
- Verificar que a alimentación estea desconectada usando un voltagprobador.
- Ensure you have the necessary tools: screwdriver, wire strippers, electrical tape, voltagprobador.
5.2 Instrucións de cableado
This receptacle supports both side wire and back wire connections.

Image 5: Receptacle Wiring Options: Side Wire and Back Wire. This diagram illustrates two wiring methods: Side Wire (for 12AWG & 14AWG) and Back Wire (for 14AWG only), showing connections for brass (black/hot), silver (white/neutral), and green (green/ground) screws, along with break-off fins.
Side Wire Connection (12AWG & 14AWG)
- Strip approximately 5/8 inch (16mm) of insulation from the wire ends.
- Connect the black (hot) wire to the brass screw.
- Connect the white (neutral) wire to the silver screw.
- Connect the green (ground) wire to the green grounding screw.
- Tighten all screws firmly to ensure good contact.
Back Wire Connection (14AWG ONLY)
- Strip approximately 5/8 inch (16mm) of insulation from the wire ends.
- Insert the stripped end of the black (hot) wire into the back wire hole adjacent to the brass screw.
- Insert the stripped end of the white (neutral) wire into the back wire hole adjacent to the silver screw.
- Connect the green (ground) wire to the green grounding screw using the side wire method.
- Tighten the screws to secure the back-wired connections.
5.3 Mounting and Final Steps
- Carefully fold the wires into the electrical box.
- Fixe o receptáculo á caixa eléctrica usando os parafusos de montaxe proporcionados.
- Attach the wall plate over the receptacle.
- Restaurar a enerxía no interruptor ou caixa de fusibles.
- Test the receptacle to ensure proper function.
6. Instrucións de funcionamento
To use the receptacle, simply insert a compatible electrical plug into one of the two outlets. The Tamper Resistant (TR) feature may require a firm, even push to insert the plug, as the internal shutters need to be opened simultaneously by both prongs of the plug. Ensure the plug is fully seated for a secure connection.
7. Mantemento
- Limpeza: Clean the receptacle and wall plate with a soft, damp pano. Non empregue produtos de limpeza abrasivos nin disolventes. Asegúrese de que a corrente estea desconectada antes de limpar.
- Inspección periódica: Periodically inspect the receptacle for any signs of damage, loose connections, or discoloration. If any issues are found, turn off power and consult a qualified electrician.
8 Solución de problemas
- Sen enerxía:
- Check the circuit breaker or fuse box to ensure power is on.
- Verifique que todas as conexións de cableado estean seguras (asegúrese de que a electricidade estea desconectada antes de comprobalas).
- Plug Difficult to Insert:
- This is normal for Tamper Resistant (TR) receptacles. Apply firm, even pressure to insert the plug. Do not force it at an angle.
- Receptacle is Hot:
- Immediately disconnect any devices and turn off power. This could indicate an overload or a wiring issue. Consult a qualified electrician.
9. Especificacións

Image 6: Product Specification Table. This image displays a table detailing the product's specifications, including Safety Certification, Rating, Receptacle Type, Wiring Type, Grounding, Product Size, and Wall Plate inclusion.
| Especificación | Detalle |
|---|---|
| Certificación de seguridade | UL, CUL Listed |
| Rating (A, V) | 20 A 125 V |
| Tipo de receptáculo | Tamper Resistant & Weather Resistant Duplex Receptacle |
| Tipo de cableado | Back Wire & Side Wire |
| Conexión a terra | Auto-terra |
| Tamaño do produto | 4.5" x 2.75" x 0.97" |
| Material | Termoplástico |
| Cor | Negro Brillante |
10. Información da garantía
ELEGRP products are manufactured to high-quality standards. For specific warranty details, please refer to the warranty card included with your purchase or visit the official ELEGRP websitio. Garda o comprobante de compra para reclamacións de garantía.
11. Atención ao cliente
If you have any questions, require technical assistance, or need to report an issue, please contact ELEGRP customer support through the retailer's platform or the official ELEGRP website. Please have your product model number (2006W-BL5-WP) and purchase information ready.