MARSTEK Triple Power 63A

Manual do usuario do interruptor de transferencia automática MARSTEK Triple Power 63A 110/120V

Model: Triple Power 63A

1. Introdución

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the MARSTEK Triple Power 63A 110/120V Automatic Transfer Switch (ATS). This device is designed to automatically switch between three power sources (e.g., utility power, generator, inverter) to ensure a continuous and stable power supply to connected loads. It incorporates advanced protection features against overvoltage, subvoltage, and overcurrent conditions.

Please read this manual thoroughly before installation and operation to ensure safe and efficient use of the product.

2. Información de seguridade

WARNING: Risk of Electric Shock. Installation and servicing should only be performed by qualified personnel.

Safety warning showing a hand holding a voltage tester and a diagram of power off and test for electricity.

Image: Safety warning indicating to power off and test for electricity before installation. Always ensure zero voltage is detected before proceeding with any work on the device.

3. Características do produto

The MARSTEK Triple Power 63A ATS offers a range of features designed for reliable power management:

Product features highlighting intelligent protection: Overvoltage, Undervoltage, and Overcurrent Protection.

Image: Visual representation of the intelligent protection features, including overvoltage, subvoltage, and overcurrent protection, designed to safeguard connected equipment.

Comprehensive Electrical Protection details with adjustable ranges for overvoltage, subvoltage, e sobreintensidade.

Image: Detailed breakdown of the comprehensive electrical protection, showing default and adjustable values for overvoltage (>140V), undervoltage (<90V), and overcurrent (>63A).

Diagram illustrating the flexible priority phase setting, allowing L1, L2, or L3 to be set as the primary source.

Image: Diagram demonstrating the flexibility to set any input phase (L1, L2, or L3) as the primary power source, optimizing power configuration based on reliability or cost.

4. Contido do paquete

O paquete do produto inclúe:

Note: DIN rail may be included separately or integrated. Please check your packaging.

5. Especificacións

ParámetroValor
Vol. de oferta clasificadatageAC 110V (N-L1/L2/L3)
Corrente de funcionamento nominal63 Amps
Vol. Operativotage120 voltios
Velocidade de transferencia1-600s (Adjustable, 5s Default)
Vida Mecánica106 operacións
Sobrevoltage ProtecciónAdjustable 120V-300V (Default 140V)
Undervoltage ProtecciónAdjustable 80V-210V (Default 90V)
Protección contra sobrecorrienteAdjustable 1A-63A (Default 63A)
Modo de operaciónACENDIDO APAGADO
Tipo de contactoNormalmente pechado
Tipo de conectorEnchufar
TerminalParafuso
Tipo de circuíto3 vías
Material de contactoCobre
Dimensións do produto (L x W x H)4.3 x 3.5 x 3.3 polgadas
Peso15.2 onzas
Product dimensions diagram showing length, width, and height, along with a table of key specifications.

Image: Diagram illustrating the physical dimensions of the ATS and a summary table of its key electrical and mechanical specifications.

6. Instalación

6.1 Montaxe en carril DIN

The MARSTEK ATS is designed for quick and easy installation on a standard DIN rail.

  1. Ensure all power sources are disconnected and verified as de-energized.
  2. Align the back panel display of the ATS with the DIN rail.
  3. Press the latch located on the bottom of the ATS.
  4. Insert the ATS onto the DIN rail.
  5. Release the latch to secure the ATS firmly in place. You should hear a "click" sound.
Four-step diagram showing simple DIN rail installation: align, press latch, insert, release latch.

Image: Step-by-step visual guide for installing the ATS onto a DIN rail, demonstrating the alignment, latch pressing, insertion, and latch release process.

6.2 Diagrama de cableado

Refer to the following diagram for correct wiring connections. Ensure all connections are tight and properly insulated.

Wiring diagram for the automatic transfer switch, showing connections for N, L1, L2, L3 inputs and N, L outputs.

Image: Detailed wiring diagram illustrating the input connections for Neutral (N), Line 1 (L1), Line 2 (L2), Line 3 (L3), and output connections for Neutral (N) and Line (L).

7. Funcionamento

7.1 Power-On and Initial State

Once wired and power is applied, the ATS will perform a self-check. The LED display will show the voltage levels of the connected sources. The device will automatically select the primary source (as configured) if it is stable and within acceptable parameters.

Multi-function digital adjustment panel with LED display showing voltage and current, and menu options for parameter customization.

Image: Close-up of the multi-function digital adjustment panel, featuring a high-definition LED display for real-time voltage and current monitoring, alongside menu options for customizing parameters.

7.2 Automatic Switching Logic

The ATS continuously monitors the voltage and stability of all three connected power sources. The switching logic is as follows:

Diagram illustrating the three-power automatic switching process between normal state, voltage abnormality, and backup power sources.

Image: Flowchart depicting the automatic switching mechanism, showing how the ATS transitions between the normal power source and backup sources in response to power outages ou voltage abnormalities, and reverts once stability is restored.

7.3 Axuste de parámetros

The ATS features a digital adjustment panel for customizing various parameters. Use the 'M' (Menu), 'Up' (Digit+), and 'Down' (Digit-) buttons to navigate and adjust settings.

Refer to the on-screen menu for specific navigation and adjustment procedures. Always ensure settings are appropriate for your electrical system and connected loads.

8. Mantemento

The MARSTEK ATS is designed for minimal maintenance. However, regular checks can ensure optimal performance and longevity:

WARNING: Always disconnect power before performing any maintenance or cleaning.

9 Solución de problemas

ProblemaCausa posibleSolución
O dispositivo non se acende.No input power; incorrect wiring; internal fault.Verify input power to L1/L2/L3 and N terminals. Check wiring against diagram. If power is present and wiring is correct, contact support.
No automatic transfer.Backup source not stable; primary source still active; incorrect settings (e.g., transfer delay).Consulta voltage of backup sources. Ensure primary source is truly unavailable. Review transfer delay settings (rE).
Frequent tripping (Overvoltage/Undervoltage/Overcurrent).Unstable power supply; load exceeds rating; protection settings too sensitive.Monitor power quality. Reduce load if exceeding 63A. Adjust protection thresholds (oU, UU, oC) if appropriate for your system, but do not exceed safe limits.
GFI/GFCI trips when using a generator.Generator has a neutral-ground bond, creating multiple bonding points when connected to a house system.This ATS is designed for systems where neutral and ground are bonded at a single point (e.g., main service panel). If using a neutral-bonded portable generator, consult a qualified electrician for proper isolation or alternative wiring solutions to avoid ground fault issues.
LED display shows "Fault".Indicates an error condition (e.g., overvoltage, subvoltage, overcurrent).Check the specific fault indicator (L1, L2, L3, Fault LED). Address the underlying power issue or load condition. Review protection settings.

10. Garantía e soporte

MARSTEK products are manufactured to high-quality standards. For warranty information, please refer to the terms and conditions provided at the point of purchase or contact MARSTEK customer support.

If you encounter any issues not covered in this manual or require further assistance, please contact MARSTEK customer service through your retailer or the official MARSTEK websitio.

Documentos relacionados - Triple Power 63A

Preview Manual de usuario e especificacións técnicas do contador de enerxía trifásico MARSTEK CT002
Manual de usuario completo e especificacións técnicas para o contador de enerxía trifásico MARSTEK CT002. Abarca o produto en máis deview, guía de instalación, detalles técnicos, precaucións de seguridade, integración de aplicacións e información sobre a garantía.
Preview Портативна зарядна станція MARSTEK M1200: Посібник користувача
Посібник користувача для портативної зарядної станції MARSTEK M1200. Дізнайтеся про характеристики, функції, безпечне використання та обслуговування цогодож безнайтеся Empresa de MARSTEK ENERGY CO., LIMITED.
Preview Manual do usuario do contador de enerxía trifásico MARSTEK TPM-100CTW
Manual de usuario do MARSTEK TPM-100CTW, un contador de enerxía trifásico montado en carril DIN deseñado para monitorizar o consumo de enerxía doméstico. As características inclúen unha antena integrada para unha maior intensidade do sinal e conectividade Bluetooth para o seguimento e o control en tempo real.
Preview Manual do usuario da central eléctrica móbil MARSTEK M5000-N
User manual for the MARSTEK M5000-N Movable Power Station. Learn how this device converts solar energy to AC power, stores it in its battery, and provides portable power for everyday use and emergencies. Covers features, operation, safety, and app integration.
Preview Manual do usuario de MARSTEK VENUS - C/E: Guía de instalación, funcionamento e mantemento
Manual de usuario completo para o sistema de almacenamento de enerxía acoplado a CA MARSTEK VENUS - C/E. Abarca todo o produtoview, instalación, control por aplicación, mantemento, resolución de problemas, especificacións técnicas e información de seguridade para os modelos Venus-C (2.5 kWh) e Venus-E (5 kWh).
Preview Marstek Venus E Batterij & CT003 Meter Installatiehandleiding
Gedetailleerde instalaiehandleiding para Marstek Venus E batería en CT003 P1-poort slimme meterlezer, inclue app-configuration, firmware-updates e integration slimme meterlezer.