MARSTEK Dual Power 63A

Manual do usuario do interruptor de transferencia automático/manual MARSTEK 63A 110V

Model: Dual Power 63A

Marca: MARSTEK

1. Introdución

Welcome to the user manual for the MARSTEK 63A 110V Automatic/Manual Transfer Switch. This device is engineered to provide seamless power management by automatically or manually switching between primary (L1) and backup (L2) power sources. It features an LED display for real-time monitoring and incorporates comprehensive protection features to ensure the safety and reliability of your electrical system.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your transfer switch. Please read it thoroughly before installation and use.

2. Información importante de seguridade

Always follow basic safety precautions when installing, operating, and maintaining this product to reduce the risk of fire, electric shock, and injury to persons.

  • A instalación debe ser realizada por un electricista cualificado de acordo con todos os códigos eléctricos locais e nacionais.
  • Disconnect all power sources before performing any installation, wiring, or maintenance.
  • Non opere o interruptor se parece estar danado.
  • Asegúrese de conectar a terra adecuada para evitar descargas eléctricas.
  • This device is designed for indoor use in a dry environment.
  • Manteña os nenos lonxe dos aparellos eléctricos.

3. Contido do paquete

  • 1 x MARSTEK 63A 110V Automatic/Manual Transfer Switch
  • 1 x DIN Rail
  • 1 x Manual de usuario (este documento)

4. Produto rematadoview

The MARSTEK 63A 110V Automatic/Manual Transfer Switch is a compact device designed for reliable power source switching. It features an LED display for real-time voltage and operational status, and offers both automatic and manual control options.

Características clave

  • Automatic or Manual Switching: Seamless transfer between primary (L1) and backup (L2) power sources.
  • Protección integral: Inclúe overvoltage, subvoltage, protección contra sobrecorriente.
  • Monitorización en tempo real: High-definition LED display shows voltage e estado.
  • Fácil instalación: DIN rail mountable design.
  • Aplicación ampla: Suitable for commercial, industrial, and residential backup power systems.

Diagrama do produto

MARSTEK 63A 110V Automatic/Manual Transfer Switch with DIN rail
Fronte view of the MARSTEK 63A 110V Automatic/Manual Transfer Switch, showing the LED display and input/output terminals, alongside a DIN rail for mounting.

This image displays the main unit of the transfer switch, highlighting its compact design and the integrated LED display. The DIN rail is also shown, indicating its mounting method.

MARSTEK Automatic Transfer Switch with Overvoltage, Undervoltage, and Overcurrent Protection icons
Visual representation of the multiple protection features integrated into the transfer switch, including overvoltage, subvoltage, protección contra sobrecorriente.

This image illustrates the built-in safety mechanisms of the transfer switch, emphasizing its capability to protect connected devices from electrical instability through overvoltage, subvoltage, and overcurrent safeguards.

5. Especificacións

ParámetroValor
ModeloDual Power 63A
Valoración actual63 Amps
Vol. Operativotage120 voltios
Modo de operaciónON-AUTO-MANUAL
Dimensións do produto (L x W x H)4.3 x 3.5 x 3.3 polgadas
Peso13.12 onzas
Tipo de contactoNormalmente pechado
Tipo de conectorEnchufar
TerminalParafuso
Tipo de circuíto2 vías
Material de contactoCobre
Frecuencia nominal50/60 Hz
Sobrevoltage Limiar de protecciónAC140V
Undervoltage Limiar de protecciónAC90V

6. Configuración e instalación

Proper installation is crucial for the safe and reliable operation of the transfer switch. This device is designed for DIN rail mounting.

Antes da instalación

  • Ensure all power sources are disconnected at the main breaker before beginning installation.
  • Verifique que o voltage and current ratings of the transfer switch match your electrical system requirements.
  • Prepare the installation location, ensuring it is dry, well-ventilated, and easily accessible.

Diagrama de cableado

Wiring diagram for MARSTEK Automatic Transfer Switch
Detailed wiring diagram showing connections for N1, L1, N2, L2 inputs and N, L outputs, along with LED display indicators.

This diagram illustrates the correct wiring connections for the transfer switch. It shows the input terminals for primary power (N1, L1) and backup power (N2, L2), and the output terminals (N, L) to the load. The diagram also labels the LED indicators for L1 output, L2 output, overvoltage, e undervoltage, as well as the menu/reset and manual ON/OFF buttons.

Pasos de instalación

  1. Mount the DIN rail securely in your electrical panel or enclosure.
  2. Attach the transfer switch onto the DIN rail.
  3. Connect the primary power source (N1, L1) to the designated input terminals.
  4. Connect the backup power source (N2, L2) to the designated input terminals.
  5. Connect the load (N, L) to the output terminals.
  6. Comprobe dúas veces que todas as conexións sexan estancas e correctas.
  7. Once all wiring is complete and verified, restore power to the system.

7. Funcionamento

The MARSTEK transfer switch offers both automatic and manual operation modes.

Modo automático

Automatic/Manual Transfer Switch operation diagram
Diagram illustrating automatic switching between L1 (Public Power) and L2 (Generator or Inverter).

In automatic mode, the switch prioritizes the primary power source (L1). If L1 fails or experiences voltage fluctuations (undervoltage ou overvoltage), the switch will automatically transfer the load to the backup power source (L2). When L1 is restored and stable, the switch will automatically transfer the load back to L1.

Modo manual

Instructions for manual use of the ATS switch
Instructions for manually closing L1 or L2 using the control buttons on the transfer switch.

The transfer switch can be manually operated using the buttons on the front panel.

  • To close L1: Press the button labeled "L1" (often indicated by an up arrow or similar icon). Press again to open L1.
  • To close L2: Press the button labeled "L2" (often indicated by a down arrow or similar icon). Press again to open L2.

In manual mode, the automatic transfer function is overridden. Ensure you understand the implications of manual switching before use.

LED Display and Indicators

The LED display provides real-time information about the system status.

  • The main display shows voltage readings for the active power source.
  • L1: Indicates L1 output is active.
  • L2: Indicates L2 output is active.
  • >V: Sobrevoltage indicador luminoso.
  • <V: Undervoltage indicador luminoso.
  • M: Menu selection/Reset button.
  • CONXUNTO: Manual ON/OFF button.

8. Mantemento

The MARSTEK transfer switch requires minimal maintenance.

  • Periodically inspect the wiring connections to ensure they are secure and free from corrosion.
  • Manteña o dispositivo limpo e libre de po e residuos. Use un pano seco e suave para limpar.
  • Non use produtos de limpeza ou disolventes abrasivos.
  • Asegúrese de que haxa unha ventilación axeitada arredor da unidade para evitar o sobrequecemento.

Warning: Always disconnect all power sources before performing any maintenance.

9 Solución de problemas

Esta sección ofrece solucións a problemas comúns cos que podes atoparte.

ProblemaCausa posibleSolución
O dispositivo non se acende.No input power; incorrect wiring; internal fault.Check main breakers and power sources. Verify all wiring connections. If the problem persists, contact support.
No automatic transfer.Device in manual mode; power source within acceptable limits; fault in L1 or L2 detection.Ensure the device is set to automatic mode. Check voltage levels of both L1 and L2. Contact support if automatic transfer fails despite correct settings.
Sobrevoltage (>V) or Undervoltage (<V) indicator lit.Vol. De entradatage outside specified range.Consulta o voltage of the active power source. The device will automatically switch if the voltage is outside the set parameters (AC140V overvoltage, AC90V undervoltage). Address the power source issue.
Overcurrent protection triggered.Load exceeds the 63A current rating.Reduce the connected load. Ensure total current draw does not exceed 63 Amps.

10. Garantía e soporte

For warranty information and technical support, please refer to the MARSTEK official websitio web ou póñase en contacto co seu vendedor. Garde o recibo da compra como proba de compra.

Manufacturer: JUXIANG

Marca: MARSTEK

Documentos relacionados - Dual Power 63A

Preview Manual de usuario e especificacións técnicas do contador de enerxía trifásico MARSTEK CT002
Manual de usuario completo e especificacións técnicas para o contador de enerxía trifásico MARSTEK CT002. Abarca o produto en máis deview, guía de instalación, detalles técnicos, precaucións de seguridade, integración de aplicacións e información sobre a garantía.
Preview Портативна зарядна станція MARSTEK M1200: Посібник користувача
Посібник користувача для портативної зарядної станції MARSTEK M1200. Дізнайтеся про характеристики, функції, безпечне використання та обслуговування цогодож безнайтеся Empresa de MARSTEK ENERGY CO., LIMITED.
Preview Manual do usuario do contador de enerxía trifásico MARSTEK TPM-100CTW
Manual de usuario do MARSTEK TPM-100CTW, un contador de enerxía trifásico montado en carril DIN deseñado para monitorizar o consumo de enerxía doméstico. As características inclúen unha antena integrada para unha maior intensidade do sinal e conectividade Bluetooth para o seguimento e o control en tempo real.
Preview Manual do usuario de MARSTEK VENUS-D: Instalación, funcionamento e mantemento
Manual de usuario completo para o sistema de almacenamento de microenerxía fotovoltaica MARSTEK VENUS-D, que abrangue a instalación, os modos de funcionamento, o mantemento, a resolución de problemas e as especificacións técnicas dos modelos MST-HI-2200 e MST-E2.5ST-D.
Preview Manual do usuario da central eléctrica móbil MARSTEK M5000-N
User manual for the MARSTEK M5000-N Movable Power Station. Learn how this device converts solar energy to AC power, stores it in its battery, and provides portable power for everyday use and emergencies. Covers features, operation, safety, and app integration.
Preview Manual do usuario de MARSTEK VENUS - C/E: Guía de instalación, funcionamento e mantemento
Manual de usuario completo para o sistema de almacenamento de enerxía acoplado a CA MARSTEK VENUS - C/E. Abarca todo o produtoview, instalación, control por aplicación, mantemento, resolución de problemas, especificacións técnicas e información de seguridade para os modelos Venus-C (2.5 kWh) e Venus-E (5 kWh).