MIWA AUR.CS

MIWA AUR.CS Backset 76mm Electric Lock Case Instruction Manual

Model: AUR.CS

1. Introdución

This instruction manual provides essential information for the proper installation, operation, and maintenance of the MIWA AUR.CS Backset 76mm Electric Lock Case. Please read this manual thoroughly before proceeding with any procedures to ensure safe and correct usage. This product is designed for specific door applications and requires careful handling.

2. Produto rematadoview

The MIWA AUR.CS is an electric lock case designed for secure door applications. It features a 76mm backset and is part of the AU series, compatible with AUT, AUR, AUTA, and AURA systems. The lock case includes a function switching type electric mechanism and is identifiable by the AU26 engraving.

Características principais:

MIWA AUR.CS Electric Lock Case with wiring harness and faceplate

Figura 2.1: Fronte view of the MIWA AUR.CS electric lock case, showing the internal mechanism, wiring harness, and a separate faceplate. The wiring is color-coded for electrical connections.

MIWA AUR.CS Electric Lock Case with faceplate attached

Figura 2.2: Arriba abaixo view of the MIWA AUR.CS electric lock case with the faceplate attached. This view highlights the overall assembly and mounting points.

Lado view of MIWA AUR.CS Electric Lock Case

Figura 2.3: Lado view of the MIWA AUR.CS electric lock case, illustrating its profile and the position of the latch bolt and deadbolt mechanisms. The model number and other markings are visible on the side.

Close-up of MIWA AU26 engraving on faceplate

Figura 2.4: Detallado view of the faceplate, clearly showing the "MIWA AU26" engraving, which identifies the specific model and series of the lock case.

3. Especificacións

EspecificaciónDetalle
MarcaMIWA
Número de modelo do produtoAUR.CS
Dimensións do produto (LxWxH)24 x 2.5 x 9.5 cm
CorST (Silver)
Retroceso76 mm
Gravado02 MIWA AU26
Compoñentes incluídosNone (Lock case body only)
Fabricantemiwa

4. Configuración e instalación

Installation of the MIWA AUR.CS electric lock case requires precision and knowledge of door hardware and electrical wiring. It is highly recommended that installation be performed by a qualified professional to ensure proper function, security, and compliance with local building codes.

Directrices xerais de instalación:

  1. Preparación: Ensure the door is properly prepared with the correct mortise cutout for the lock case and faceplate. Verify the backset measurement (76mm) matches the door preparation.
  2. Mounting the Lock Case: Insert the lock case into the mortise cutout in the door edge. Secure it with appropriate screws through the mounting holes on the faceplate.
  3. Cableado: Connect the electrical wiring harness (as shown in Figure 2.1) to the door's power supply and access control system according to the system's wiring diagram. Pay close attention to polarity and ensure all connections are secure and insulated.
  4. Cylinder and Trim Installation: Install the appropriate door cylinder, handles, and trim plates as per their respective instructions. Ensure they operate smoothly with the lock case mechanism.
  5. Instalación da placa de peche: Install the strike plate on the door frame, aligning it precisely with the latch bolt and deadbolt of the lock case.
  6. Proba: After installation, thoroughly test all functions of the lock, including electrical operation, manual key override, and handle operation, before final use.

Refer to the specific wiring diagrams provided with your access control system for detailed electrical connections. Incorrect wiring can damage the lock case or the access control system.

5. Funcionamento

The MIWA AUR.CS electric lock case operates in conjunction with an external access control system. Its function switching type allows for various operational modes depending on the system configuration.

Operación básica:

Always ensure the door closes completely for the lock to engage properly. Do not force the door if the lock mechanism is not fully retracted.

6. Mantemento

Regular maintenance helps ensure the longevity and reliable operation of your MIWA AUR.CS electric lock case.

Procedementos de mantemento:

If you notice any significant issues or damage, contact a qualified technician for repair or replacement.

7 Solución de problemas

This section addresses common issues you might encounter with the MIWA AUR.CS electric lock case.

ProblemaCausa posibleSolución
Lock does not engage/disengage electrically.No power, faulty wiring, access control system issue, damaged solenoid.Check power supply to the lock. Verify wiring connections. Consult access control system manual. Contact a technician if solenoid is suspected.
Door does not close properly or latch bolt binds.Misaligned strike plate, door sag, debris in mortise.Adjust strike plate alignment. Check door hinges. Clean mortise area.
Key/thumbturn operation is stiff.Lack of lubrication, internal debris, worn cylinder.Apply silicone lubricant to the mechanism. Clean out any debris. If worn, consider cylinder replacement.
Ruídos pouco habituais durante o funcionamento.Internal wear, loose components, foreign object.Inspect for loose screws or components. If noise persists, professional inspection is recommended.

For issues not listed here or if solutions do not resolve the problem, contact a qualified locksmith or the product manufacturer for assistance.

8. Garantía e soporte

Warranty information for the MIWA AUR.CS electric lock case is typically provided by the seller or manufacturer at the time of purchase. Please retain your proof of purchase for warranty claims.

For technical support, service, or to inquire about replacement parts, please contact your authorized MIWA dealer or the point of purchase. Provide them with the product model number (AUR.CS) and any relevant details about your issue.

Documentos relacionados - AUR.CS

Preview Sistema de xestión de fechaduras eléctricas para hoteis MIWA: características e vantaxes
Descubra o sistema de xestión de fechaduras eléctricas para hoteis MIWA, que inclúe seguridade RFID avanzada, codificadores USB (NFC/BLE), acceso por chave móbil e programación flexible de tarxetas de hóspedes/persoal para hoteis. Obteña información sobre o seu software de recepción e as funcións de fechadura.
Preview Manual de referencia rápida para tableta con sistema de peche de tarxeta para hotel MIWA ALV2
A quick reference guide for programming and managing MIWA ALV2 hotel cardlock systems using the DTU tablet. It covers lock programming for guest, common, special, and non-guest doors, clearing lock sequences, setting the lock clock, interrogating locks, and understanding lock indicator lights.
Preview MIWA ALV2 Hotel Card Lock System: RFID Access Control Solutions
Discover the MIWA ALV2 Hotel Card Lock System, a leading RFID-based access control solution for the hospitality sector. This system offers enhanced security, user-friendly operation, flexible master key management, and seamless integration with hotel management software. Learn about its features, card variations, and upgrade options.
Preview MIWA ALV3M Series Hotel Card Lock System: Operation and Maintenance Manual
This document provides comprehensive operation and maintenance instructions for the MIWA ALV3M Series Hotel Card Lock System, including functional overviews, operating procedures, periodic maintenance guidelines, and compliance information.
Preview MIWA ALV2 (ALVB) Series Card Issuing System for Hotels
Rematada integralview of the MIWA ALV2 (ALVB) series card issuing system, detailing its features for hotel access control, guest card management, security, and mobile key integration.
Preview Manual de referencia rápida para tableta con sistema de peche de tarxeta para hotel MIWA ALV2
Unha guía de referencia rápida para o sistema de peche con tarxeta para hoteis MIWA ALV2, que detalla as operacións da tableta para programar, xestionar e solucionar problemas de peches de hoteis.