📘 SIMARINE manuals • Free online PDFs
Logotipo de SIMARINE

SIMARINE Manuals & User Guides

SIMARINE manufactures advanced battery monitoring systems and digital switching solutions designed for the marine and recreational vehicle markets.

Tip: include the full model number printed on your SIMARINE label for the best match.

About SIMARINE manuals on Manuals.plus

SIMARINE is a specialized electronics developer focused on high-precision battery monitoring and digital switching systems for the marine and caravan industries. Based in Slovenia, the company is best known for its PICO battery monitor, which sets a new standard in design and functionality by providing detailed insights into battery health, tank levels, and temperatures.

With a philosophy grounded in energy efficiency and user-friendly design, SIMARINE offers a comprehensive ecosystem of digital shunts, tank modules, and inclinometers. Their products enable boat and RV owners to easily manage complex electrical systems through intuitive indicators and mobile app integration, ensuring safety and reliability during travel.

SIMARINE manuals

Manuais máis recentes de manuals+ elaborado para esta marca.

Manual de usuario del inclinómetro Simarine SDI01

2 de xuño de 2025
Simarine SDI01 Inclinometer Specifications Product Name: SDI01 Inclinometer Version: V1.2 Features: High-resolution digital inclinometer for pitch and roll with manual calibration Compatibility: Fully compatible with existing SIMARINE monitoring systems Note:…

Manual de usuario de Simarine SN01 N2K Gateway

23 de decembro de 2024
Simarine SN01 N2K Gateway Especificacións Operating Voltage Range: N2K backbone Connectivity Temperature range: 0,6 mA Power consumption at 12V: 111.80 x 77.52 x 32.11 mm / 4.40 x 3.05 x…

Manual de usuario del interruptor de luz SIMARIN Nereide

1 de outubro de 2023
SIMARINE Nereide Light Switch The Nereide Light Switch is a product designed for controllinglighting fixtures. It comes in two different colors, black and silver. Product Usage Instructions Installation Ensure that…

Manual de usuario del inclinómetro digital SIMARINE SDI01

Manual de usuario
User manual for the SIMARINE SDI01 Digital Inclinometer, detailing its features, installation, connection, calibration, configuration, and technical specifications for marine applications. Learn how to integrate and use this high-resolution pitch…

Simarine Nereide 2 Digital Switching Benutzerhandbuch

Manual de usuario
Das Simarine Nereide 2 Digital Switching System ist eine fortschrittliche Lösung für die Steuerung elektrischer Systeme an Bord von Booten. Dieses Benutzerhandbuch bietet detaillierte Anleitungen zur Installation, Konfiguration und Bedienung…

Manual de usuario del monitor de batería SIMARIN PICO

Manual de usuario
Manual de usuario para o SIMARINE PICO, un monitor de baterías CC avanzado para aplicacións mariñas. Ofrece orientación sobre a instalación, configuración e funcionamento da batería, o tanque, a temperatura e a monitorización da corrente.

Simarine SCQ25T Digital Shunt and Tank Module User Manual

Manual de usuario
User manual for the Simarine SCQ25T digital shunt and tank module, detailing its features, installation, technical specifications, and troubleshooting for monitoring voltage, current, liquid levels, and temperature in marine and…

SIMARINE manuals from online retailers

Simarine Pico One Battery Monitor Set User Manual

pico_one • July 9, 2025
Comprehensive user manual for the Simarine Pico One Battery Monitor Set. Learn about installation, operation, features, and troubleshooting for multi-voltage battery, tank, and temperature monitoring systems.

Simarine ST107 Tank Level Module User Manual

ST107 • 20 de xuño de 2025
Comprehensive user manual for the Simarine ST107 Tank Level Module, covering installation, operation, maintenance, troubleshooting, specifications, and warranty information.

SIMARINE support FAQ

Preguntas frecuentes sobre manuais, rexistro e asistencia técnica para esta marca.

  • Why is my Simarine shunt not visible on the PICO unit?

    If the shunt is not visible, check that it is properly connected via the SiCOM port using a twisted pair cable. Ensure the voltage sensing input is correctly installed and terminals are not switched.

  • What should I do if the current value shows a wrong sign?

    If the current value is negative when it should be positive (or vice versa), the shunt may be installed backwards. Ensure the battery minus terminal connects to the 'IN' terminal on the shunt, or switch the configuration via the PICO menu.

  • How do I calibrate a tank sensor on the Simarine system?

    Tank sensors must be calibrated via the PICO menu or the Simarine mobile app to show the correct levels. Refer to the PICO manual for the specific calibration procedure for your sensor type.

  • What type of cable is recommended for the SiCOM connection?

    For SiCOM connections longer than 5 meters, it is recommended to use a 2x2x0.25 mm2 twisted pair cable to ensure reliable data transmission.